{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848428","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848428","canonicalUrl":"https://aoctrl.com/schneider/LV848428","factsUrl":"https://aoctrl.com/api/mcp/products/LV848428","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT MTZ2, LV848428, drawout circuit breaker, 4P, 1250 A at 40 °C, H2 100 kA 415 V AC, Category B.","salesMarkdown":"The LV848428 is a Schneider Electric MasterPact MTZ2 drawout circuit breaker — 4-pole, rated 1250 A at 40 °C, with an H2 performance class delivering 100 kA breaking capacity at 415 V AC. It's a Category B breaker per IEC 60947-2, meaning it's designed for full selectivity in downstream coordination, not just a standalone fault interrupter. The drawout chassis lets you rack the breaker out for maintenance or replacement without disturbing the power connections — that's the whole point of the form factor. With the chassis installed, the unit measures 403 mm deep, 556 mm wide, and 439 mm high; without the chassis, it's 300 mm deep and 493 mm wide. Built to EN/IEC 60947-1, -2, and Annex H for air circuit breakers, plus IEC 61557-12 for performance measurement. Pollution degree 3, rated insulation voltage 1000 V AC, impulse withstand 12 kV.","metaTitle":"LV848428 MasterPact MTZ2 Drawout Circuit Breaker, 1250 A, 10","metaDescription":"Schneider Electric LV848428 MasterPact MTZ2 drawout circuit breaker, 1250 A rated at 40 °C, H2 100 kA at 415 V AC. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Voltage":"690 V AC 50/60 Hz","IP Rating":"IP30","Application":"Power distribution protection","Control Type":"Push-button","Product Status":"Active","Terminal Pitch":"115 mm","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"1000 V AC 50/60 Hz","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Connection Surface Top":"Front Rear","Electrical Life Cycles":"10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23 A: 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23 A: 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3","Mechanical Life Cycles":"25000 cycles with periodic preventive maintenance","Connection Surface Bottom":"Front Rear","Main Product Or Component Type":"Circuit breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/714bb4d47497710fe379a19c943cef27.pdf","sourceUrl":"https://www.se.com/th/en/product/LV848428/circuit-breaker-frame-masterpact-mtz2-12h2-drawout-for-micrologic-x-1250a-100ka-415vac-icu-4p-right-neutral/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848428/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848428","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848428 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}