{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848498WW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848498WW","canonicalUrl":"https://aoctrl.com/schneider/LV848498WW","factsUrl":"https://aoctrl.com/api/mcp/products/LV848498WW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPacT series, MicroLogic 2.0 Xi electronic control unit, LI protection, 690 V AC, drawout mounting.","salesMarkdown":"The LV848498WW is a Schneider Electric MicroLogic 2.0 Xi electronic control unit for MasterPacT air circuit breakers. It is a wired-control device with an LCD display (128 x 96 pixels) and provides equipment protection, monitoring, and control for distribution networks at 50/60 Hz. The trip unit offers LI protection — long-time overload (ANSI 49) and instantaneous short-circuit (ANSI 50) — with adjustable long-time delay in 0.5 s steps and electronic thermal memory. It is rated for operational voltages up to 690 V AC (+/- 10 %). ## Fit and mounting — what the drawout form factor means for your panel This control unit is a drawout-mounted module, meaning it plugs into the MasterPacT breaker cradle and can be removed without disturbing the main power wiring — useful for panel access, retrofit, or swap-out during a line changeover. Pole configurations supported are 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN, with neutral protection settings selectable per the configuration. Trip unit ratings cover a wide band from 400 A through 6300 A, so the same control unit board can serve multiple breaker frame sizes with the appropriate sensor. The LV848498WW integrates a power meter measuring current (I1, I2, I3, Iavg, IN RMS, Ig RMS), voltage (phase-to-phase and phase-to-neutral), active/reactive/apparent power and energy, power factor, frequency, THD, and unbalance. Accuracy is Class 0.5 for voltage unbalance, Class 1 for active energy, and Class 2 for THD(V). For MTZ1 frames, current accuracy is +/- 0.5 % from 40 to 1600 x 1.2 A. Measurement voltage range is 208...828 V AC phase-to-phase, 120...480 V AC phase-to-neutral, with a frequency measurement range of 40...70 Hz. The measurement category is IV per IEC 61010-2-30, suitable for utility-side metering at the service entrance. ## Compliance and environmental — what documentation supports qualification The control unit complies with EN/IEC 60947-2 (circuit-breakers), EN/IEC 60092-202 (marine), EN/IEC 60947-1, EN/IEC 60255-1 (measuring relays), and EN/IEC 61010-1 (safety). EMC immunity covers electrostatic discharge, electromagnetic fields, fast transients, surge (1.2/50 µs), conducted RF, and conducted/radiated emissions Class A per CISPR 22. Overvoltage category IV per IEC 61010-1. Relative humidity rating is 95 % at 55 °C per IEC 60068-2-30. Operating altitude is up to 5000 m with voltage derating to 560 V AC. Note: the unit is not approved for wet locations per IEC 61010-1.","metaTitle":"LV848498WW MicroLogic 2.0 Xi Control Unit, MasterPacT, 690 V","metaDescription":"LV848498WW MicroLogic 2.0 Xi electronic control unit for MasterPacT breakers. LI protection, drawout mount, 690 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Poles":"4P 3P","Range":"MasterPacT","Standards":"EN/IEC 60947-2 EN/IEC 60092-202 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1","Control type":"Wired control","Display type":"LCD display - 128 x 96 pixels","Network type":"AC","Metering type":"Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage","Mounting mode":"Drawout","Accuracy class":"Class 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)","Data recording":"Time stamping Data logs Event logs Alarm logs Maintenance logs Min/max of instantaneous values","Thermal memory":"Yes","Protection type":"Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50","lifecycle_stage":"current","Pollution degree":"3 conforming to IEC 60947-1","Trip unit rating":"400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A","Device short name":"MicroLogic 2.0 Xi","Energy management":"Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy","Mounting location":"Indoor use only","Network frequency":"50/60 Hz","Relative humidity":"95 % at 55 °C conforming to IEC 60068-2-30","Device application":"Equipment protection, monitoring and control","Operating altitude":"<= 5000 m with operational voltage derating 560 V AC","Measurement voltage":"208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral","Type of measurement":"Power meter","Measurement accuracy":"Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %","Measurement category":"Category IV conforming to IEC 61010-2-30","Overvoltage category":"IV conforming to IEC 61010-1","Trip unit technology":"Electronic","Product or component type":"Control unit","Neutral protection setting":"1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)","Circuit breaker application":"Distribution IEC standard","Communication port protocol":"USB peer to peer 115 kbauds","Frequency measurement range":"40...70 Hz","Protected poles description":"3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN","Environmental characteristic":"Wet location not approved for use conforming to IEC 61010-1","Electromagnetic compatibility":"Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22","Trip unit protection functions":"LI","[Ue] rated operational voltage":"690 V AC, +/- 10 %","Long time delay adjustment type":"Adjustable in step of 0.5 s","Zone selective interlocking ZSI":"Without","Network and machine diagnosis type":"System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state","Ambient air temperature for operation":"-25...70 °C (operating) -35 °C (for start-up of product)","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Ir] long time pick-up adjustment range":"0.4...1 x In adjustable in step of 1 A","Instantaneous pick-up adjustment type Ii":"Adjustable","[Ii] instantaneous pick-up adjustment range":"1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app","[Li Mode] Instantaneous Delay Adjustment Range":"20 ms in standard"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/319bb710bdbcf230981cdfd48d1dff0c.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848498WW/micrologic-2-0xi-control-unit-no-wireless-masterpact-mtz2-mtz3-drawout-circuit-breakers-li-protections/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848498WW/alternatives.json"},"ai":{"faq":[{"question":"What is LV848498WW's listed poles (4P 3P) on this component line?","answer":"The control unit supports 4P and 3P configurations, with protected pole options including 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN."},{"question":"What is LV848498WW's listed range (MasterPacT) on this component line?","answer":"The range is MasterPacT, Schneider Electric's family of air circuit breakers for distribution and generator protection."},{"question":"What compliance documentation does this brand provide for LV848498WW (RoHS, REACH, UL, IEC)?","answer":"The control unit is certified to EN/IEC 60947-2, EN/IEC 60092-202, EN/IEC 60947-1, EN/IEC 60255-1, and EN/IEC 61010-1. EMC compliance covers CISPR 22 Class A emissions. RoHS and REACH documentation is typically available from the manufacturer's product support page."},{"question":"Where can I buy LV848498WW?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848498WW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848498WW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}