{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848499","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848499","canonicalUrl":"https://aoctrl.com/schneider/LV848499","factsUrl":"https://aoctrl.com/api/mcp/products/LV848499","rawCanonicalId":null},"summary":{"shortDescription":"Schneider LV848499 Masterpact Mtz — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The LV848499 is a Schneider MasterPact MTZ MicroLogic 5.0 X control unit — an electronic trip unit with LSI protection, rated for 3-pole drawout mounting. It integrates Bluetooth 4.0 LE, NFC, and USB peer-to-peer communication, and a 128 x 96 pixel LCD display for local metering and diagnostics. The unit supports a trip unit rating range from 400 A to 6300 A and is designed for distribution IEC standard applications. ## Communication & metering Three onboard interfaces — Bluetooth 4.0 LE at 30 kbit/s, NFC per ISO 15963, and USB at 115 kbaud — allow local configuration and data retrieval without opening the panel door. The LCD cycles through a full metering suite: phase and neutral currents, line-to-line and line-to-neutral voltages, active/reactive/apparent power, power factor, energy (import/export/total), demand values, frequency, phase sequence, earth leakage, and harmonic distortion (THD). Event logs, alarm logs, min/max snapshots, and maintenance logs are stored onboard. ## Compliance & environment The LV848499 carries IEC 60947-2, IEC 60947-1, IEC 60255-1, IEC 60092-202, and IEC 61010-1 standards. Measurement category IV per IEC 61010-2-30 qualifies it for utility-level metering. EMC immunity covers electrostatic discharge (IEC 61000-4-2), radiated fields (IEC 61000-4-3), fast transients (IEC 61000-4-4), surge 1.2/50 µs (IEC 61000-4-5), and conducted RF (IEC 61000-4-6); conducted and radiated emissions meet Class A per CISPR 22. Operating ambient temperature down to -25 °C, altitude up to 5000 m, humidity 95%.","metaTitle":"Schneider LV848499 MicroLogic 5.0 X control unit, 3-pole, drawout","metaDescription":"Schneider MasterPact MTZ LV848499 MicroLogic 5.0 X electronic trip unit, 3 poles, drawout, Bluetooth/NFC/USB, LCD, LSI protection, IEC 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Poles":"3P 4P","Range":"MasterPacT","Standards":"EN/IEC 60947-2 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 60092-202 EN/IEC 61010-1","Display type":"LCD display - 128 x 96 pixels","Network type":"AC","Metering type":"Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage","Mounting mode":"Drawout","Accuracy class":"Class 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)","Data recording":"Event logs Data logs Time stamping Alarm logs Min/max of instantaneous values Maintenance logs","Thermal memory":"Yes","Protection type":"Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51","lifecycle_stage":"current","Pollution degree":"3 conforming to IEC 60947-1","Trip unit rating":"400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A","Device short name":"MicroLogic 5.0 X","Energy management":"Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy","Mounting location":"Indoor use only","Network frequency":"50/60 Hz","Relative humidity":"95 % at 55 °C conforming to IEC 60068-2-30","Device application":"Equipment protection, monitoring and control","Operating altitude":"<= 5000 m with operational voltage derating 560 V AC","Measurement voltage":"208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral","Type of measurement":"Power meter","Measurement accuracy":"Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %","Measurement category":"Category IV conforming to IEC 61010-2-30","Overvoltage category":"IV conforming to IEC 61010-1","Trip unit technology":"Electronic","Product or component type":"Control unit","Neutral protection setting":"1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)","Circuit breaker application":"Distribution IEC standard","Communication port protocol":"Bluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer conforming to ISO 15963 USB peer to peer 115 kbauds","Frequency measurement range":"40...70 Hz","Protected poles description":"3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN","Environmental characteristic":"Wet location not approved for use conforming to IEC 61010-1","Electromagnetic compatibility":"Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC, +/- 10 %","Long time delay adjustment type":"Adjustable in step of 0.5 s","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable","Network and machine diagnosis type":"System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state","Ambient air temperature for operation":"-25...70 °C (operating) -35 °C (for start-up of product)","[Tr] Long-Time Delay Adjustment Range":"12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir","[Ir] long time pick-up adjustment range":"0.4...1 x In adjustable in step of 1 A","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.4 s I²t=on 0...0.4 s I²t=off","Instantaneous pick-up adjustment type Ii":"Adjustable","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app","[Ii] instantaneous pick-up adjustment range":"2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off","[Li Mode] Instantaneous Delay Adjustment Range":"0 ms in fast 20 ms in standard"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,919.75","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b2e634f128f77ac9fb4f153e358aca2f.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848499/micrologic-5-0-x-control-unit-for-drawout-masterpact-mtz2-mtz3/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV848499/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848499","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848499 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}