{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848747","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848747","canonicalUrl":"https://aoctrl.com/schneider/LV848747","factsUrl":"https://aoctrl.com/api/mcp/products/LV848747","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2 12 HA10, LV848747, switch disconnector, 1250 A, 3 poles, drawout, chassis mount, EN/IEC 60947-3.","salesMarkdown":"## Switch disconnector for distribution — 1250 A drawout The Schneider Electric LV848747 is a MasterPact MTZ2 12 HA10 switch disconnector rated for 1250 A at 1150 V AC, 50/60 Hz, in a three-pole drawout chassis configuration. The 1250 A continuous rating (Ie) at 1150 V AC places this unit in the high-current distribution tier — sized for main incoming feeders or large bus risers in industrial switchgear. The AC-23A and AC-3 utilization categories mean it handles switching of motor loads and mixed resistive-inductive loads within that current envelope; AC-23A specifically covers occasional switching of individual motors and other highly inductive loads. Short-circuit performance is defined by a rated short-time withstand current (Icw) of 50 kA for 1 s and 50 kA for 3 s, plus a rated short-circuit making capacity (Icm) of 105 kA peak at 1150 V. These numbers govern selectivity coordination with downstream breakers — the switch disconnector must hold closed during a fault long enough for the downstream device to clear, without welding or degrading. Drawout mounting on a dedicated chassis (connection pitch 115 mm) allows the switching element to be racked out for maintenance or replacement without de-energizing the bus — standard practice for main and tie positions in a switchboard lineup. The contact position indicator and visible-break confirmation (per EN/IEC 60947-3) give the operator a positive mechanical indication of isolation. The unit occupies a 441 mm wide × 439 mm high × 403 mm deep footprint on a chassis mount — sized for standard low-voltage switchgear cubicles. IP30 protection limits ingress to tools and small wires; the enclosure it mounts in provides the overall panel rating. Operating ambient temperature range is -25 to 70 °C, with storage from -40 to 85 °C — sufficient for most indoor industrial installations without derating, though the 70 °C upper operating limit may require ventilation in hot-climate or high-load cubicles. Rated impulse withstand voltage (Uimp) of 12 kV aligns with distribution-level surge coordination.","metaTitle":"Schneider Electric LV848747 MasterPact MTZ2 12 HA10 Switch D","metaDescription":"Schneider Electric LV848747 MasterPact MTZ2 switch disconnector, 1250 A rated operational current, 3 poles, drawout chassis mount. EN/IEC 60947-3, 50 kA Icw for 1 s. Active product","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"403 mm","Range":"MasterPact","Width":"441 mm","title":"LV848747","Height":"439 mm","Standards":"EN/IEC 60947-3","description":"Switch disconnector Masterpact MTZ2 12 HA 10, 1250 A, 3 poles, drawout","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","Visible break":"No","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Chassis","Pollution degree":"3 conforming to EN/IEC 60947-4-1","Network frequency":"50/60 Hz","Performance Level":"HA10","Poles description":"3P","Device application":"Distribution","Utilisation category":"AC-23A AC-3","Electrical durability":"AC-23A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Mechanical durability":"25000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3","IP degree of protection":"IP30","Switch-disconnector name":"MasterPact MTZ2 12 HA10","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to EN/IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1250 V AC 50/60 Hz conforming to EN/IEC 60947-3","[Ie] rated operational current":"1250 A AC 50/60 Hz 1150 V","[Ue] rated operational voltage":"1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to EN/IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to EN/IEC 60947-3 50 kA during 3 s conforming to EN/IEC 60947-3","[Icm] rated short-circuit making capacity":"105 kA peak 1150 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d02b865f54173eca3438dfa788635fd2.pdf","sourceUrl":"https://www.se.com/vn/en/product/LV848747/switch-disconnector-masterpact-mtz2-12-ha-10-1250-a-3-poles-drawout/"},"ai":{"faq":[{"question":"Where can I buy LV848747 and how do I get a price?","answer":"The LV848747 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is LV848747's rated operational current and voltage?","answer":"The LV848747 is rated for 1250 A (Ie) at 1150 V AC, 50/60 Hz, in AC-23A and AC-3 utilization categories."},{"question":"What compliance standards does LV848747 meet?","answer":"The LV848747 conforms to EN/IEC 60947-3 for switch-disconnector performance, including suitability for isolation. Pollution degree 3 per EN/IEC 60947-4-1 is also declared."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848747","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848747 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}