{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848748","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848748","canonicalUrl":"https://aoctrl.com/schneider/LV848748","factsUrl":"https://aoctrl.com/api/mcp/products/LV848748","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2 16 HA10 switch-disconnector, LV848748, 1600 A, 3 poles, drawout, 1150 V AC, 50 kA Icw, EN/IEC 60947-3.","salesMarkdown":"## Switch-disconnector for high-current distribution The Schneider Electric LV848748 is a MasterPact MTZ2 16 HA10 switch-disconnector rated for 1600 A at 1150 V AC, 50/60 Hz, in a 3-pole drawout chassis mount. It meets EN/IEC 60947-3 and is certified for isolation (suitability for isolation: yes). The 1600 A continuous rating means it handles main feeder or large-load disconnect duty in LV distribution switchgear — not a motor-starter device, but a line-side isolator with make/break capability under load (utilisation categories AC-23A and AC-3). Rated short-time withstand current (Icw) is 50 kA for 1 s and also 50 kA for 3 s — that tells you the switch can carry a fault current for up to 3 seconds without damage, which is critical for selective coordination downstream. Rated short-circuit making capacity (Icm) is 105 kA peak at 1150 V AC, meaning it can close onto a bolted fault at that level. Rated impulse withstand voltage (Uimp) is 12 kV, covering surge environments in industrial switchgear. These figures, combined with pollution degree 3 and the -25 to 70 °C operating range, suit it for unconditioned electrical rooms and heavy industrial installations. ## Drawout mounting and panel integration Drawout mounting means the switch-disconnector slides into a fixed chassis — no need to disconnect power cables for removal, which speeds maintenance and replacement on live-bus switchgear. The chassis mount and 115 mm connection pitch are standard for MasterPact MTZ2 drawout cassettes. Dimensions: 441 mm wide, 439 mm high, 403 mm deep. IP30 protection means it is touch-safe but not sealed — install inside a cabinet rated for the environment.","metaTitle":"LV848748 MasterPact MTZ2 16 HA10 Switch-Disconnector, 1600 A","metaDescription":"Schneider Electric LV848748 MasterPact MTZ2 16 HA10 switch-disconnector, 1600 A, 3P drawout, 1150 V AC, 50 kA Icw, EN/IEC 60947-3. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"403 mm","Range":"MasterPact","Width":"441 mm","title":"LV848748","Height":"439 mm","Standards":"EN/IEC 60947-3","description":"Switch-disconnector Masterpact MTZ2 16 HA 10 - 1600 A - 3P drawout","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","Visible break":"No","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Chassis","Pollution degree":"3 conforming to EN/IEC 60947-4-1","Network frequency":"50/60 Hz","Performance Level":"HA10","Poles description":"3P","Device application":"Distribution","Utilisation category":"AC-23A AC-3","Electrical durability":"AC-23A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Mechanical durability":"25000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3","IP degree of protection":"IP30","Switch-disconnector name":"MasterPact MTZ2 16 HA10","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to EN/IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1250 V AC 50/60 Hz conforming to EN/IEC 60947-3","[Ie] rated operational current":"1600 A AC 50/60 Hz 1150 V","[Ue] rated operational voltage":"1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to EN/IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to EN/IEC 60947-3 50 kA during 3 s conforming to EN/IEC 60947-3","[Icm] rated short-circuit making capacity":"105 kA peak 1150 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c5428b4735d285218c4656a8918b7e43.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV848748/switchdisconnector-masterpact-mtz2-16-ha-10-1600-a-3p-drawout/"},"ai":{"faq":[{"question":"What is LV848748's rated operational current and voltage?","answer":"The LV848748 is rated for 1600 A at 1150 V AC, 50/60 Hz."},{"question":"What standards does LV848748 comply with?","answer":"It complies with EN/IEC 60947-3 and is certified for isolation."},{"question":"What is the short-circuit withstand rating of LV848748?","answer":"Rated short-time withstand current (Icw) is 50 kA for 1 s and also 50 kA for 3 s; rated short-circuit making capacity (Icm) is 105 kA peak at 1150 V AC."},{"question":"Where can I buy LV848748 and what is the lead time?","answer":"The LV848748 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures are published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848748","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848748 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}