{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV848758","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV848758","canonicalUrl":"https://aoctrl.com/schneider/LV848758","factsUrl":"https://aoctrl.com/api/mcp/products/LV848758","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric MasterPact MTZ2 16 HA10 switch disconnector, LV848758, 1600 A rated operational current, 105 kA Icm at 1150 VAC, 4 poles, drawout mounting, EN/IEC 60947-3.","salesMarkdown":"## MasterPact MTZ2 16 HA10 — 1600 A Switch Disconnector for Distribution The LV848758 is a Schneider Electric MasterPact MTZ2 16 HA10 switch disconnector rated for 1600 A continuous current at 1150 V AC, 50/60 Hz, in a 4-pole drawout chassis configuration. The part is built to EN/IEC 60947-3 and is certified for isolation (visible-break indicator confirms the contacts are open). ## Short-Time Withstand and Fault Coordination Rated short-time withstand current (Icw) is 50 kA for both 1 s and 3 s durations — a 3 s rating that gives downstream protection devices time to clear without stressing the switch. Utilisation categories AC-23A and AC-3 cover switching of motor loads and mixed resistive-inductive circuits, though at 1600 A this is primarily a distribution disconnect rather than a motor starter. ## Drawout Construction and Panel Integration Drawout mounting (chassis-supported) allows the switch to be racked out for maintenance or replacement without disturbing the main bus connections — a standard requirement for main breakers in switchgear lineups. Physical footprint: 556 mm wide × 439 mm high × 403 mm deep. Connection pitch is 115 mm. IP30 protection means it is intended for enclosed panel installation, not open washdown areas. Mechanical durability is rated at 25,000 cycles with periodic preventive maintenance; electrical durability is 500 cycles at full rated voltage in AC-23A duty — a disconnect that is not cycled daily, but is robust for infrequent switching.","metaTitle":"LV848758 MasterPact MTZ2 16 HA10 Switch Disconnector, 1600 A","metaDescription":"LV848758 MasterPact MTZ2 16 HA10 switch disconnector, 1600 A rated operational current, 105 kA Icm at 1150 VAC, 4P drawout, EN/IEC 60947-3. Active production, sourced to order. Req","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"403 mm","Range":"MasterPact","Width":"556 mm","title":"LV848758","Height":"439 mm","Standards":"EN/IEC 60947-3","description":"Switch disconnector, MasterPact MTZ2 16HA10, 1600A, 105kA/1150VAC 50/60Hz (Icm), 4P, drawout","Control type":"Push-button","Network type":"AC","Mounting mode":"Drawout","Visible break":"No","lifecycle_stage":"current","Connection pitch":"115 mm","Mounting support":"Chassis","Pollution degree":"3 conforming to EN/IEC 60947-4-1","Network frequency":"50/60 Hz","Performance Level":"HA10","Poles description":"4P","Device application":"Distribution","Utilisation category":"AC-23A AC-3","Electrical durability":"AC-23A: 500 cycles 1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Mechanical durability":"25000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-3","IP degree of protection":"IP30","Switch-disconnector name":"MasterPact MTZ2 16 HA10","Product or component type":"Switch disconnector","Suitability for isolation":"Yes conforming to EN/IEC 60947-3","Contact position indicator":"Yes","[Ui] rated insulation voltage":"1250 V AC 50/60 Hz conforming to EN/IEC 60947-3","[Ie] rated operational current":"1600 A AC 50/60 Hz 1150 V","[Ue] rated operational voltage":"1150 V AC 50/60 Hz conforming to EN/IEC 60947-3","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"12 kV conforming to EN/IEC 60947-3","[Icw] rated short-time withstand current":"50 kA during 1 s conforming to EN/IEC 60947-3 50 kA during 3 s conforming to EN/IEC 60947-3","[Icm] rated short-circuit making capacity":"105 kA peak 1150 V AC at 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/764f556803a27e6775adb08d4e55d001.pdf","sourceUrl":"https://www.se.com/th/en/product/LV848758/switch-disconnector-masterpact-mtz2-16ha10-1600a-105ka-1150vac-50-60hz-icm-4p-drawout/"},"ai":{"faq":[{"question":"What are the key ratings of LV848758?","answer":"Rated operational current is 1600 A at 1150 V AC. Short-circuit making capacity is 105 kA peak. Short-time withstand is 50 kA for 1 s and 3 s. It is a 4-pole drawout switch disconnector compliant with EN/IEC 60947-3."},{"question":"Where can I buy LV848758 and how is it quoted?","answer":"The LV848758 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What compliance documentation does Schneider Electric provide for LV848758?","answer":"The LV848758 is certified to EN/IEC 60947-3 for switch-disconnector performance and isolation suitability. It carries a pollution degree 3 rating and 12 kV impulse withstand. For RoHS, REACH, and specific UL/CSA documentation, request the manufacturer's compliance declaration through the RFQ process."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV848758","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV848758 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}