{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV947285","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV947285","canonicalUrl":"https://aoctrl.com/schneider/LV947285","factsUrl":"https://aoctrl.com/api/mcp/products/LV947285","rawCanonicalId":null},"summary":{"shortDescription":"MicroLogic Active 5.0A control unit, no wireless, MasterPacT MTZ1/MTZ2/MTZ3, fixed circuit breakers, LSI protections","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Poles":"4P 3P","Range":"MasterPacT","Standards":"EN/IEC 60947-2 EN/IEC 60092-202 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1","Control type":"Wired control","Display type":"LCD display - 320 x 240 pixels","Network type":"AC","Metering type":"Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Demand current I1, I2, I3, In, Iavg Frequency Phase sequence total Unbalance current","Mounting mode":"Fixed","Data recording":"Data logs Event logs Alarm logs Time stamping Maintenance logs Min/max of instantaneous values","Thermal memory":"Yes","Protection type":"Overload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51","lifecycle_stage":"unknown","Pollution degree":"3 conforming to IEC 60947-1","Trip unit rating":"250 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A","Device short name":"MicroLogic Active 5.0 A","Mounting location":"Indoor use only","Network frequency":"50/60 Hz","Relative humidity":"95 % at 55 °C conforming to IEC 60068-2-30","Device application":"Equipment protection, monitoring and control","Operating altitude":"<= 5000 m with operational voltage derating 560 V AC","Type of measurement":"Ammeter","Measurement accuracy":"Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 1.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 1.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 1.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1.5 % Ground fault current Ig: +/- 10 % Frequency: +/- 0.005 Hz Unbalance current: +/- 0.5 %","Measurement category":"Category IV conforming to IEC 61010-2-30","Overvoltage category":"IV conforming to IEC 61010-1","Trip unit technology":"Electronic","Product or component type":"Control unit","Neutral protection setting":"1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)","Circuit breaker application":"Distribution IEC standard","Communication port protocol":"NFC peer to peer 28800 bauds conforming to ISO 15963 USB peer to peer 115 kbauds","Frequency measurement range":"40...70 Hz","Protected poles description":"3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN","Environmental characteristic":"Wet location not approved for use conforming to IEC 61010-1","Electromagnetic compatibility":"Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22","Trip unit protection functions":"LSI","[Ue] rated operational voltage":"690 V AC, +/- 10 %","Long time delay adjustment type":"Adjustable in step of 0.5 s","Zone selective interlocking ZSI":"With","Short-time delay adjustment type":"Adjustable","Network and machine diagnosis type":"System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state","Ambient air temperature for operation":"-25...70 °C (operating) -35 °C (for start-up of product)","[Tr] Long-Time Delay Adjustment Range":"0.5...30 s at 6 x Ir","[Ir] long time pick-up adjustment range":"0.4...1 x In adjustable in step of 1 A","[Tsd] Short-Time Delay Adjustment Range":"0.1...0.8 s I²t=on 0...0.8 s I²t=off","Instantaneous pick-up adjustment type Ii":"Adjustable","[Isd] short-time pick-up adjustment range":"1.5...10 x Ir adjustable in step of 0.1 x Ir","[Ii] instantaneous pick-up adjustment range":"2...15 x In adjustable in step of 0.1 x In Ii enable on/off","[Li Mode] Instantaneous Delay Adjustment Range":"20 ms in standard"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,684.41 – $1,768.63","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fb9f74aa8a1f8a3c85c77964aea33912.pdf","sourceUrl":"https://www.se.com/ie/en/product/LV947285/micrologic-active-5-0a-control-unit-no-wireless-masterpact-mtz1-mtz2-mtz3-fixed-circuit-breakers-lsi-protections/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV947285/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV947285","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV947285 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}