{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV948001","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV948001","canonicalUrl":"https://aoctrl.com/schneider/LV948001","factsUrl":"https://aoctrl.com/api/mcp/products/LV948001","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker frame, MasterPacT MTZ2 08H1, for MicroLogic Active, 800A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Range":"MasterPacT","Depth (D)":"297 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2","Width (W)":"422 mm","Height (H)":"352 mm","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPacT MTZ2 Active","Mounting mode":"Fixed","Sensor rating":"400 A 630 A 800 A","lifecycle_stage":"unknown","Connection pitch":"115 mm","Mounting support":"Base plate Rails","Performance type":"H1 66 kA 440 V AC","Pollution degree":"3 conforming to IEC 60664-1","Device short name":"MTZ2 08 H1","Poles description":"3P","Upside connection":"Front Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"800 A at 40 °C","Downside connection":"Front Rear","Selectivity category":"Category B","Electrical durability":"10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"25000 cycles with maintenance","Power dissipation in W":"42 W","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP3X conforming to EN/IEC 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"14 W","Temperature derating table":"40 °C ( 800 A ) 45 °C ( 800 A ) 50 °C ( 800 A ) 55 °C ( 800 A ) 60 °C ( 800 A ) 65 °C ( 800 A ) 70 °C ( 800 A )","Maximum closing response time":"70 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"66 kA 0.5 s 66 kA 1 s 36 kA 3 s","[Icm] rated short-circuit making capacity":"145 kA 220/415 V AC at 50/60 Hz 145 kA 440 V AC at 50/60 Hz 145 kA 525 V AC at 50/60 Hz 145 kA 690 V AC at 50/60 Hz","[Ics] rated service short-circuit breaking capacity":"66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 525 V AC 50/60 Hz 66 kA at 690 V AC 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 525 V AC 50/60 Hz 66 kA at 690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,460.22 – $2,583.25","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c1f6b65a12cac5c7e55f591d93bdd7f9.pdf","sourceUrl":"https://www.se.com/th/en/product/LV948001/circuit-breaker-frame-masterpact-mtz2-08h1-for-micrologic-active-800a-66ka-440vac-50-60hz-icu-3p-fixed/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV948001/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV948001","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV948001 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}