{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LV948333","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LV948333","canonicalUrl":"https://aoctrl.com/schneider/LV948333","factsUrl":"https://aoctrl.com/api/mcp/products/LV948333","rawCanonicalId":null},"summary":{"shortDescription":"Circuit breaker frame, MasterPacT MTZ3 40H1, for MicroLogic Active, 4000A, 100kA/440VAC (Icu), 4P, drawout right neutral","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Range":"MasterPacT","Depth (D)":"Drawout circuit breaker with chassis: 403 mm Drawout circuit breaker without chassis: 300 mm","Standards":"EN/IEC 60947-1 EN/IEC 60947-2","Width (W)":"Drawout circuit breaker with chassis: 1016 mm Drawout circuit breaker without chassis: 953 mm","Height (H)":"Drawout circuit breaker with chassis: 479 mm Drawout circuit breaker without chassis: 298 mm","Control type":"Push-button","Control unit":"Without control unit","Product name":"MasterPacT MTZ3 Active","Mounting mode":"Drawout","Sensor rating":"2000 A 2500 A 3200 A 4000 A","lifecycle_stage":"unknown","Connection pitch":"230 mm","Mounting support":"Base plate Rails","Neutral position":"Right","Performance type":"H1 100 kA 440 V AC","Pollution degree":"3 conforming to IEC 60664-1","Device short name":"MTZ3 40 H1","Poles description":"4P","Upside connection":"Rear","Device application":"Power distribution protection","Operating altitude":"0...2000 m without derating 2000 m...5000 m with derating","[In] rated current":"4000 A at 40 °C","Downside connection":"Rear","Selectivity category":"Category B","Electrical durability":"1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2","Maximum breaking time":"25 ms","Mechanical durability":"10000 cycles with maintenance","Power dissipation in W":"900 W","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP3X conforming to EN/IEC 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2","Power dissipation per pole":"225 W","Temperature derating table":"40 °C ( 4000 A ) 45 °C ( 4000 A ) 50 °C ( 4000 A ) 55 °C ( 4000 A ) 60 °C ( 4000 A ) 65 °C ( 4000 A ) 70 °C ( 4000 A )","Maximum closing response time":"80 ms","[Ui] rated insulation voltage":"1000 V AC 50/60 Hz","[Ue] rated operational voltage":"690 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"12 kV","[Icw] rated short-time withstand current":"100 kA 0.5 s 100 kA 1 s 100 kA 3 s","[Icm] rated short-circuit making capacity":"220 kA 220/415 V AC at 50/60 Hz 220 kA 440 V AC at 50/60 Hz 220 kA 525 V AC at 50/60 Hz 220 kA 690 V AC at 50/60 Hz","[Ics] rated service short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 525 V AC 50/60 Hz 100 kA at 690 V AC 50/60 Hz","[Icu] rated ultimate short-circuit breaking capacity":"100 kA at 220/415 V AC 50/60 Hz 100 kA at 440 V AC 50/60 Hz 100 kA at 525 V AC 50/60 Hz 100 kA at 690 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7b19b83c8b6c995c2c4ce6ccaea3adaf.pdf","sourceUrl":"https://www.se.com/sg/en/product/LV948333/circuit-breaker-frame-masterpact-mtz3-40h1-for-micrologic-active-4000a-100ka-440vac-icu-4p-drawout-right-neutral/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LV948333/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LV948333","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LV948333 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}