{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX0FH008","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX0FH008","canonicalUrl":"https://aoctrl.com/schneider/LX0FH008","factsUrl":"https://aoctrl.com/api/mcp/products/LX0FH008","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor coil, LX0FH008, 220...230 V AC/DC control circuit, 50...400 Hz AC or DC standard.","salesMarkdown":"The LX0FH008 is a replacement contactor coil for the TeSys F range from Schneider Electric. It is the coil assembly that, when energized, pulls in the contactor's main power poles and auxiliary contacts. The control circuit accepts 220...230 V AC across 50...400 Hz, or the same voltage range on DC, making it flexible for panels with mixed control supplies. Coil resistance measures 25.77 Ohm for the latching winding and 4090 Ohm for the unlatching winding at 68 °F (20 °C). Operating time is 50...100 ms unlatching and 45...50 ms latching. If your customer's AVL requires a current-production part, a deviation request will be needed. The 220...230 V AC/DC control voltage covers standard 230 V line-to-neutral control circuits common in European and Asian panels. The AC 50...400 Hz range means it works on 50 Hz mains and also on 60 Hz or higher-frequency supplies used in some aerospace or marine gear. The DC standard acceptance means a 220 V DC battery bank or rectified supply will also pull the coil in — useful for UPS-backed control buses. The latching voltage limits of 0.85...1.1 Uc mean the coil must see at least 187 V and no more than 253 V to reliably latch. Outside that band, the contactor may chatter or fail to close. The unlatching limits are the same range, so the drop-out voltage is not a separate spec — the coil releases when voltage falls below the lower threshold or is interrupted.","metaTitle":"Schneider Electric LX0FH008 TeSys F Contactor Coil, 220-230","metaDescription":"TeSys F contactor coil LX0FH008, 220-230 V AC/DC control voltage. Obsolete lifecycle stage. Sourced to order against RFQ. Specifications: 25.77 Ohm latching coil resistance, 1 Mcyc","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Operating time":"50...100 ms unlatching 45...50 ms latching","lifecycle_stage":"current","Device short name":"LX0FH","Average resistance":"25.77 Ohm latching 68 °F (20 °C) 4090 Ohm unlatching 68 °F (20 °C)","Control circuit type":"AC 50...400 Hz DC standard","Mechanical durability":"1 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"120 cyc/h 104 °F (40 °C)","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"220...230 V AC 50...400 Hz 220...230 V DC","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1e08f4a9c2fecdd4a5ba6092436680ab.pdf","sourceUrl":"https://www.se.com/ie/en/product/LX0FH008/tesys-f-contactor-coil-lx0fh-220-230-v-ac-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX0FH008/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LX0FH008?","answer":"There is no official successor order code listed. The replacement path is a parametric match within the TeSys F coil family. You will need to verify the contactor frame size and control voltage against the existing panel wiring. A deviation from the customer's AVL may be required if the BOM calls out LX0FH008 specifically."},{"question":"What is the control voltage for LX0FH008?","answer":"The control circuit voltage is 220...230 V AC across 50...400 Hz, or 220...230 V DC. The latching and unlatching voltage limits are 0.85...1.1 Uc, so the coil reliably operates between approximately 187 V and 253 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX0FH008","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX0FH008 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}