{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX0FJ060","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX0FJ060","canonicalUrl":"https://aoctrl.com/schneider/LX0FJ060","factsUrl":"https://aoctrl.com/api/mcp/products/LX0FJ060","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, contactor coil, LX0FJ060, 230/110 V AC/DC, 50-100 ms unlatching, 40-75 ms latching.","salesMarkdown":"The LX0FJ060 is a replacement coil for the TeSys F contactor range, offered in a dual-voltage variant accepting 230 V or 110 V AC/DC on the control circuit at 40...400 Hz. The control circuit voltage limits are specified as 0.85...1.1 Uc for both latching and unlatching, so the coil holds in reliably across an 85% to 110% band of the nominal control voltage — useful when the control transformer is shared with other loads and may sag under peak draw. Operating time is 50...100 ms for unlatching and 40...75 ms for latching. That window matters when sequencing contactors in a reversing starter or bypass circuit: the slower unlatching edge (up to 100 ms) means the main contactor may still be closed when the reversing contactor picks up, so interlocking via auxiliary contacts or a delay-on timer is needed to prevent a phase-to-phase short. ## Integration notes The coil resistance at 20 °C is 29.72 Ohm for the latching winding and 408.7 Ohm for the unlatching winding. That difference lets you verify the correct coil is installed with an ohmmeter before energizing the panel — a quick continuity check against the table saves a blown coil if the wrong voltage variant was kitted. For a high-duty application like a rapid-reversing conveyor or a press control, check that the duty cycle stays under that rate — sustained operation above 120 cyc/h will accelerate wear and may cause the coil to overheat.","metaTitle":"Schneider LX0FJ060 TeSys F Contactor Coil, 230/110 V AC/DC","metaDescription":"Active TeSys F contactor coil LX0FJ060 for 230 V or 110 V AC/DC control circuits. 50-100 ms unlatching, 40-75 ms latching. 1 Mcycles mechanical durability. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX0FJ060","description":"TeSys F - contactor coil - LX0FJ - 230,110 V AC/DC","Operating time":"50...100 ms unlatching 40...75 ms latching","lifecycle_stage":"current","Device short name":"LX0FJ","Average resistance":"29.72 Ohm latching at 20 °C 408.7 Ohm unlatching at 20 °C","Control circuit type":"AC/DC at 40...400 Hz","Mechanical durability":"1 Mcycles","Maximum operating rate":"120 cyc/h 40 °C","Product or component type":"Contactor coil","[Uc] control circuit voltage":"230 V AC/DC 40...400 Hz 110 V AC/DC 40...400 Hz","Control circuit voltage limits":"Latching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/01e2337b4802890793ea773ae93fa540.pdf","sourceUrl":"https://www.se.com/sg/en/product/LX0FJ060/tesys-f-contactor-coil-lx0fj-230110-v-ac-dc/"},"ai":{"faq":[{"question":"What is the operating time for LX0FJ060?","answer":"Unlatching time is 50...100 ms; latching time is 40...75 ms. The slower unlatching edge (up to 100 ms) requires interlocking in reversing or bypass circuits."},{"question":"What control voltages does LX0FJ060 accept?","answer":"It accepts 230 V or 110 V AC/DC on the control circuit at 40...400 Hz, with control circuit voltage limits of 0.85...1.1 Uc for both latching and unlatching."},{"question":"What is the mechanical durability of LX0FJ060?","answer":"Rated at 1 Mcycles mechanical durability, with a maximum operating rate of 120 cycles per hour at 40 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX0FJ060","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX0FJ060 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}