{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D2M5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D2M5","canonicalUrl":"https://aoctrl.com/schneider/LX1D2M5","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D2M5","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D LX1D2M5 contactor coil, 220 V AC 50 Hz, 60 VA inrush, 7 VA hold-in, AC control circuit.","salesMarkdown":"## TeSys D replacement coil, 220 V AC 50 Hz The LX1D2M5 is a replacement contactor coil in the TeSys D range, designed to fit the full line of TeSys D contactors. It is a 220 V AC 50 Hz coil with a control circuit type of AC. Inrush power draw is 60 VA at 50 Hz, dropping to 7 VA hold-in once the contactor is sealed. This ratio is typical for AC-operated contactor coils — the inrush surge saturates the magnetic circuit, and the hold-in power reflects the lower steady-state current through the coil. ## Coil voltage tolerance and thermal limits The control circuit voltage limits are 0.8...1.1 Uc at temperatures up to 55 °C (131 °F). This means the coil will pick up reliably at 176 V AC and must not see more than 242 V AC continuously at the rated ambient. Below the 0.8 Uc threshold the magnetic force may not overcome the contact spring pressure, causing chattering or failure to close. Above 1.1 Uc the coil temperature rise accelerates, shortening insulation life. ## Active lifecycle and sourcing Sourced through authorized distribution channels.","metaTitle":"Schneider LX1D2M5 TeSys D contactor coil, 220 V AC 50 Hz","metaDescription":"Schneider Electric LX1D2M5 replacement coil for TeSys D contactors. 220 V AC 50 Hz coil, 60 VA inrush, 7 VA hold-in. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1D2M5","Category":"22341-CONTACTOR,D,K,&F ACCESS","Coil type":"AC 50 Hz","description":"contactor coil, TeSys D LX1D, 220 V AC 50 Hz","lifecycle_stage":"current","Inrush power in VA":"60 VA 50 Hz","Control circuit type":"AC","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"220 V AC 50 Hz","Control circuit voltage limits":"0.8...1.1 Uc (at <131 °F (55 °C))","Hold-in power consumption in VA":"7 VA 50 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$58.24 – $76.49","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/id/en/product/LX1D2M5/contactor-coil-tesys-d-lx1d-220-v-ac-50-hz/"},"ai":{"faq":[{"question":"What are the inrush and hold-in power ratings for LX1D2M5?","answer":"Inrush power is 60 VA at 50 Hz; hold-in power is 7 VA at 50 Hz. The inrush-to-hold ratio is typical for AC-operated contactor coils and determines the sizing of the control transformer supplying the coil circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D2M5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D2M5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}