{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D2S6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D2S6","canonicalUrl":"https://aoctrl.com/schneider/LX1D2S6","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D2S6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D replacement contactor coil, LX1D2 series, 575 V AC 60 Hz, for 9 to 18 A contactors, without built-in suppressor module.","salesMarkdown":"## 575 V AC 60 Hz coil for TeSys D contactors The LX1D2S6 is a replacement coil from the TeSys D range, designed to fit 9 to 18 A contactors in that family. It operates on a 575 V AC 60 Hz control circuit — a non-standard voltage that narrows the pool of drop-in alternatives. The coil draws 70 VA inrush at 60 Hz (cos φ 0.75) and holds in at 7.5 VA (cos φ 0.3). The closed-circuit inductance is 119 H, with an average DC resistance of 3482 Ω at 20 °C. These values matter for sizing the control transformer and verifying the PLC output relay can handle the inrush without contact welding. ## Obsolete — sourcing through independent channels Schneider Electric has marked the LX1D2S6 as obsolete. No official successor order code is listed in the manufacturer's lifecycle record. For a line-down situation or a BOM freeze, the part is available through independent surplus and broker channels — quantities are lot-specific and confirmed at RFQ. The control circuit voltage limits are 0.8 to 1.1 Uc at 60 Hz (up to 55 °C ambient). If the replacement coil must operate at a different voltage or frequency, the entire contactor assembly may need to be swapped rather than just the coil. ## No built-in suppressor — plan for external snubbing This coil ships without a built-in suppressor module. In a panel with a PLC or electronic controller on the same control circuit, an external RC snubber or varistor across the coil terminals is standard practice to limit the inductive kickback on de-energisation. The TeSys D range offers separate suppressor modules that clip onto the coil terminals.","metaTitle":"Schneider LX1D2S6 TeSys contactor coil, 575 VAC 60 Hz","metaDescription":"Schneider Electric LX1D2S6 TeSys D replacement contactor coil, 575 V AC 60 Hz, for 9-18 A contactors.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX1D2","Average resistance":"3482 Ohm 68 °F (20 °C)","Inrush power in VA":"70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))","Control circuit type":"AC 60 Hz","Product or component type":"Contactor coil","Inductance of closed circuit":"119 H","[Uc] control circuit voltage":"575 V AC 60 Hz","Control circuit voltage limits":"Operational: 0.8...1.1 Uc at 60 Hz (at <131 °F (55 °C))","Hold-in power consumption in VA":"7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$52.11","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ca/en/product/LX1D2S6/tesys-d-contactor-coil-lx1d2-575-v-ac-60-hz-for-9-to-18-a-contactor/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1D2S6/alternatives.json"},"ai":{"faq":[{"question":"What contactors does the LX1D2S6 coil fit?","answer":"It is a TeSys D replacement coil specified for 9 to 18 A contactors in that range, operating on a 575 V AC 60 Hz control circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D2S6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D2S6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}