{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D2U6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D2U6","canonicalUrl":"https://aoctrl.com/schneider/LX1D2U6","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D2U6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D contactor coil, LX1D2U6, 240 V AC 60 Hz, for 9 to 18 A contactors, 587.4 Ohm coil resistance, 70 VA inrush, 7.5 VA hold-in.","salesMarkdown":"## What this coil does and where it fits The LX1D2U6 is a replacement coil for the TeSys D contactor family, specifically the 9 A through 18 A frame sizes. It runs on 240 V AC at 60 Hz, with an inrush of 70 VA and a hold-in draw of 7.5 VA — the drop between pickup and sealed power tells you the contactor's magnetic circuit is pulling in hard then latching. ## Lifecycle reality — obsolete, but still sourceable Schneider Electric lists this coil as obsolete. That means no factory-new production — the stock you find is either NOS (new old stock) or pulled from surplus channels. If your panel has a TeSys D contactor with a failed coil, this is the direct drop-in replacement; there is no official successor part number from Schneider. ## Coil specs that matter for the swap Coil resistance is 587.4 Ohm at 68 °F (20 °C). The inductance of the closed circuit is 21 H — that's the value you'd use if you're checking the coil with an LCR meter on a bench. ## Sourcing this coil for a repair or BOM fill Because it's obsolete, this isn't a stock-on-the-shelf item. We source it through independent distribution — quantities are confirmed at RFQ, and pricing reflects the surplus market, not factory list. If you're filling a BOM line for a panel rebuild or a line-down repair, send the RFQ with the quantity and we'll quote availability.","metaTitle":"Schneider Electric LX1D2U6 TeSys D Contactor Coil","metaDescription":"Schneider Electric LX1D2U6 TeSys D contactor coil, 240 V AC 60 Hz for 9-18 A contactors. Obsolete — sourced to order against RFQ. Resistance 587.4 Ohm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX1D2","Average resistance":"587.4 Ohm 68 °F (20 °C)","Inrush power in VA":"70 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))","Control circuit type":"AC 60 Hz","Product or Component Type":"Contactor coil","Inductance of closed circuit":"21 H","[Uc] control circuit voltage":"240 V AC 60 Hz","Control circuit voltage limits":"Operational: 0.8...1.1 Uc at 60 Hz (at <131 °F (55 °C))","Hold-in power consumption in VA":"7.5 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$85.09","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/us/en/product/LX1D2U6/tesys-d-contactor-coil-lx1d2-240-v-ac-60-hz-for-9-to-18-a-contactor/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1D2U6/alternatives.json"},"ai":{"faq":[{"question":"What contactors does the LX1D2U6 coil fit?","answer":"It fits TeSys D contactors in the 9 A to 18 A frame range. The coil voltage is 240 V AC 60 Hz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D2U6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D2U6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}