{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D4L6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D4L6","canonicalUrl":"https://aoctrl.com/schneider/LX1D4L6","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D4L6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D LX1D4L6 replacement contactor coil, 208 V AC 60 Hz control circuit, 100 VA inrush / 8.5 VA hold-in, active production.","salesMarkdown":"## Coil swap for a TeSys D contactor The LX1D4L6 is the replacement coil for a TeSys D contactor when the control voltage needs to be 208 V AC 60 Hz. It's the part you pull when the old coil opens or the line voltage changes — not a full contactor swap, just the magnet assembly. Inrush is 100 VA at 60 Hz; once the armature seals, the hold-in drops to 8.5 VA. That 12:1 ratio means the control transformer needs to handle the inrush without sagging below the 0.8 Uc dropout threshold — especially on a long cable run to the panel. ## Voltage tolerance and thermal limits Below 0.8 Uc the contactor may drop out; above 1.1 Uc the coil temperature rises and the insulation life shortens. On a warm panel near the enclosure roof, derate the supply voltage accordingly. AC 60 Hz only — this coil will not pull in reliably on 50 Hz or DC control circuits. If the site runs 50 Hz, you need the equivalent 208 V 50 Hz coil variant from the same TeSys D range.","metaTitle":"Schneider LX1D4L6 TeSys D Contactor Coil, 208 V AC 60 Hz","metaDescription":"Schneider Electric LX1D4L6 replacement coil for TeSys D contactors. 208 V AC 60 Hz, 100 VA inrush, 8.5 VA hold-in. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1D4L6","Category":"22341-CONTACTOR,D,K,&F ACCESS","Coil type":"AC 60 Hz","description":"contactor coil, TeSys D LX1D, 208 V AC 60 Hz","lifecycle_stage":"current","Inrush power in VA":"100 VA 60 Hz","Control circuit type":"AC","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"208 V AC 60 Hz","Control circuit voltage limits":"0.8...1.1 Uc (at <131 °F (55 °C))","Hold-in power consumption in VA":"8.5 VA 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$43.99","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/LX1D4L6/contactor-coil-tesys-d-lx1d-208-v-ac-60-hz/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D4L6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D4L6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}