{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D6UP6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D6UP6","canonicalUrl":"https://aoctrl.com/schneider/LX1D6UP6","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D6UP6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D series, LX1D6UP6 contactor coil, 230 V AC 60 Hz, for 80 & 95 A contactors.","salesMarkdown":"## What this coil is and what it drives The LX1D6UP6 is a TeSys D replacement coil — the LX1D6 variant — wound for 230 V AC at 60 Hz. It mates specifically with the 80 A and 95 A frame contactors in that family, so if you're swapping a failed coil on an LC1D80 or LC1D95 running on 60 Hz mains, this is the drop-in. Coil draws 220 VA inrush at 60 Hz (cos φ 0.75) and holds at 22 VA (cos φ 0.3), both at 20 °C. That inrush-to-hold ratio is typical for AC-operated contactor coils — the control transformer feeding it needs to handle the inrush without dipping below the 0.85 Uc dropout threshold at 60 Hz. Ambient range is -5 to 60 °C; maximum cycling rate is 3600 operations per hour at 60 °C. ## Suppressor note — plan for external RC or varistor This coil ships without a built-in suppressor module. If the contactor drives inductive loads or shares a control bus with PLC outputs, you will want an external RC snubber or MOV across the coil terminals. The 236.3 Ω DC resistance at 20 °C gives a baseline for sizing the suppression network.","metaTitle":"Schneider LX1D6UP6 TeSys D Contactor Coil, 230 V AC 60 Hz","metaDescription":"Active TeSys D replacement coil for 80 & 95 A contactors. 230 V AC 60 Hz, 6-10 W dissipation, 10 Mcycles mechanical life. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1D6UP6","description":"TeSys D - contactor coil - LX1D6 - 230 V AC 60 Hz for 80 & 95 A contactor","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"6...10 W at 50/60 Hz","Device short name":"LX1D6","Average resistance":"236.3 Ohm at 20 °C","Inrush power in VA":"220 VA 60 Hz cos phi 0.75 (at 20 °C)","Control circuit type":"AC at 60 Hz","Mechanical durability":"10 Mcycles","Maximum operating rate":"3600 cyc/h 60 °C","Product or component type":"Contactor coil","[Uc] control circuit voltage":"230 V AC 60 Hz","Control circuit voltage limits":"Drop-out: 0.3...0.6 Uc at 50/60 Hz (at Operational: 0.8...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at <55 °C)","Hold-in power consumption in VA":"22 VA 60 Hz cos phi 0.3 (at 20 °C)","Ambient air temperature for operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a1303ac0d1cdc5426a0083c0c18290c4.pdf","sourceUrl":"https://www.se.com/ie/en/product/LX1D6UP6/tesys-d-contactor-coil-lx1d6-230-v-ac-60-hz-for-80-95-a-contactor/"},"ai":{"faq":[{"question":"What contactors does this coil fit?","answer":"It is designed for TeSys D contactors rated 80 A and 95 A — the LC1D80 and LC1D95 frames. The coil designation LX1D6 matches that frame size."},{"question":"Does this coil have a built-in surge suppressor?","answer":"No. The coil technology is listed as 'without built-in suppressor module'. An external RC snubber or varistor should be added if the control circuit requires transient suppression."},{"question":"What is the control voltage and frequency?","answer":"230 V AC at 60 Hz. Dropout occurs between 0.3 and 0.6 Uc; pick-up requires 0.85 to 1.1 Uc at 60 Hz below 55 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D6UP6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D6UP6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}