{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D6Z6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D6Z6","canonicalUrl":"https://aoctrl.com/schneider/LX1D6Z6","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D6Z6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D, LX1D6Z6, contactor coil, 20 V AC 60 Hz, for 80 & 95 A contactors, without built-in suppressor module.","salesMarkdown":"## Coil for the 80/95 A frame The LX1D6Z6 is a replacement coil in the TeSys D line, wound for 20 V AC at 60 Hz and sized for the 80 A and 95 A contactor frames. It pulls 220 VA inrush at 0.75 power factor, then settles to 22 VA hold-in at 0.3 PF — the drop is typical of an AC-magnet coil, so the control transformer supplying it needs to handle the inrush without dipping below 0.85 Uc or the armature chatters. The coil has no built-in suppressor; if the contactor drives inductive loads, you add an RC snubber or varistor across the coil terminals externally. ## Voltage tolerance and thermal limits Operating range is 0.85 to 1.1 Uc at 60 Hz below 55 °C ambient; drop-out occurs between 0.3 and 0.6 Uc. That 0.3 floor is generous — the coil stays pulled in through a brownout down to about 6 V, which matters on a line fed by a marginal generator. Heat dissipation runs 6 to 10 W at 50/60 Hz; in a densely packed panel, that adds up. Ambient operating range is -5 to 60 °C, so it handles a warm cabinet without derating. ## Mechanical endurance and cycling Rated for 10 million mechanical cycles at a maximum operating rate of 3600 cycles per hour at 60 °C.","metaTitle":"Schneider TeSys LX1D6Z6 contactor coil, 20 VAC 60 Hz, active","metaDescription":"Schneider Electric TeSys D LX1D6Z6 contactor coil, 20 VAC 60 Hz for 80/95 A contactors. Active production. 220 VA inrush, 22 VA hold-in, 10 Mcycles mechanical durability. RFQ for p","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"20 V AC 60 Hz","Product Status":"Active","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 60 Hz","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...140 °F (-5...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a85c74c741980a9c839df4e740142e83.pdf","sourceUrl":"https://www.se.com/sg/en/product/LX1D6Z6/tesys-d-contactor-coil-lx1d6-20-v-ac-60-hz-for-80-95-a-contactor/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1D6Z6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D6Z6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D6Z6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}