{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D8K7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D8K7","canonicalUrl":"https://aoctrl.com/schneider/LX1D8K7","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D8K7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca contactor coil LX1D8K7, 100-110 V AC 50/60 Hz, 300 VA inrush, 22 VA hold, obsolete.","salesMarkdown":"The LX1D8K7 is a replacement contactor coil in the TeSys Deca range, designed to fit the LX1D8 contactor frame. It is a bare coil without a built-in suppressor module, so any RC snubber or varistor must be added externally across the coil terminals if the application requires EMI suppression or inductive-load protection for the driving PLC output. Rated for 100-110 V AC at 50/60 Hz, it draws 300 VA inrush at 50 Hz (cos φ 0.8) and settles to 22 VA hold-in power (cos φ 0.3). That 13:1 ratio between pick-up and sealed power means the control transformer must be sized for the inrush peak, not the hold-in steady state — a 100 VA transformer will drop its output voltage momentarily if the coil shares a circuit with other loads. ## Lifecycle reality and sourcing posture If you are validating a new design or a replacement for an existing panel, the coil's mechanical durability of 8 Mcycles and maximum operating rate of 2400 cycles/hour at 60 °C give a solid baseline for expected service life, but the obsolete status means you should evaluate a form-fit-function equivalent from the current TeSys range before committing to a long-term spares plan. ## Electrical characteristics that govern fit The coil's average resistance is 1.24 Ω at 20 °C, and its closed-circuit inductance is 0.09 H. These values matter for sizing the control transformer and for calculating the back-EMV if you add an external suppressor — a standard RC snubber across the coil will see that inductance as the load. Drop-out voltage is 0.3 to 0.6 Uc at 50 Hz; operational range is 0.85 to 1.1 Uc at 50 Hz below 55 °C. In practice, if your control supply sags below about 85 V AC, the coil may not pick up reliably, and it will drop out below about 55 V AC. Heat dissipation runs 3 to 8 W at 50 Hz depending on the coil state. In a densely packed panel with multiple contactors running continuously, that heat adds up — allow adequate ventilation or derating if ambient inside the enclosure approaches 60 °C.","metaTitle":"Schneider LX1D8K7 TeSys Contactor Coil, 100-110 VAC","metaDescription":"Obsolete TeSys Deca contactor coil LX1D8K7, 100-110 VAC 50/60 Hz. 300 VA inrush, 22 VA hold. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"100...110 V AC 50/60 Hz","Product Status":"Active","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Mechanical Life Cycles":"8 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/87e6c6507b0a5d30b0c3725d4ecc99a6.pdf","sourceUrl":"https://www.se.com/sg/en/product/LX1D8K7/contactor-coil-tesys-deca-lx1d8-100-110-v-ac-50-60-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1D8K7/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D8K7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D8K7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}