{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1D8Q6","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1D8Q6","canonicalUrl":"https://aoctrl.com/schneider/LX1D8Q6","factsUrl":"https://aoctrl.com/api/mcp/products/LX1D8Q6","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LX1D8Q6, contactor coil, 380 V AC 60 Hz, for 115 A contactor, without built-in suppressor module.","salesMarkdown":"It's a replacement coil for the LX1D8 series, meant to drop into the existing contactor assembly without re-engineering the panel. Key specs: inrush power of 300 VA at 60 Hz (cos φ 0.8), hold-in consumption of 22 VA (cos φ 0.3), and a coil resistance of 243.07 Ω at 20 °C. The control voltage limits are 0.85...1.1 Uc for pickup and 0.3...0.6 Uc for dropout at 55 °C. The 380 V AC 60 Hz control voltage is specific — this coil will not work on 50 Hz or DC control circuits without modification. The absence of a built-in suppressor module means you need to add an external RC snubber or varistor across the coil if driving it from a PLC output or solid-state relay, otherwise the inductive kickback can damage the control electronics. Heat dissipation of 3 to 8 W at 60 Hz means the coil generates noticeable heat inside an enclosed panel. If the contactor is in a tightly packed cabinet with other heat sources, verify the ambient stays within the -5 to 60 °C operating range to avoid premature coil failure.","metaTitle":"Schneider LX1D8Q6 TeSys contactor coil, 380 VAC 60 Hz, obsol","metaDescription":"Schneider Electric LX1D8Q6 TeSys Deca contactor coil, 380 V AC 60 Hz, for 115 A contactor. Obsolete — sourced to order against RFQ. No built-in suppressor.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"3...8 W 60 Hz","Device short name":"LX1D8","Average resistance":"243.07 Ohm 68 °F (20 °C)","Inrush power in VA":"300 VA 60 Hz cos phi 0.8 (at 68 °F (20 °C))","Control circuit type":"AC 60 Hz","Mechanical durability":"8 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"2400 cyc/h 140 °F (60 °C)","Product or Component Type":"Contactor coil","Inductance of closed circuit":"17.04 H","[Uc] control circuit voltage":"380 V AC 60 Hz","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 60 Hz (at Drop-out: 0.3...0.6 Uc at 60 Hz (at <131 °F (55 °C))","Hold-in power consumption in VA":"22 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...140 °F (-5...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b8e2bfce5911db070f28f31363474d1c.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1D8Q6/contactor-coil-tesys-deca-lx1d8-380-v-ac-60-hz-for-115-a-contactor/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1D8Q6/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LX1D8Q6?","answer":"No official successor order code is listed in the lifecycle record. The closest functional match would be a TeSys Deca coil with the same 380 V AC 60 Hz control voltage and designed for a 115 A contactor, but you would need to verify the mounting footprint and coil termination compatibility."},{"question":"What is the TeSys range for this coil?","answer":"The LX1D8Q6 belongs to the Schneider Electric TeSys range, specifically the TeSys Deca series of contactor coils."},{"question":"Does the LX1D8Q6 have a built-in suppressor module?","answer":"No, this coil is specified as 'without built-in suppressor module'. An external suppression circuit (RC snubber or varistor) is recommended when switching the coil with electronic controls."},{"question":"How do I source the LX1D8Q6?","answer":"Since the part is obsolete, it is sourced to order against an RFQ through surplus or broker channels. Submit an RFQ for current availability and pricing — no stock or lead time can be guaranteed without a live quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1D8Q6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1D8Q6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}