{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FF036","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FF036","canonicalUrl":"https://aoctrl.com/schneider/LX1FF036","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FF036","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, contactor coil LX1FF036, 36 V AC 50 Hz control circuit, 550 VA inrush power, 10 Mcycles mechanical durability.","salesMarkdown":"The Schneider Electric LX1FF036 is a contactor coil in the TeSys F range, designed to replace the coil assembly on a TeSys F contactor when the original coil fails or a different control voltage is needed. It operates on a 36 V AC 50 Hz control circuit, drawing 550 VA inrush power at 68 °F (20 °C) with a 0.3 power factor, then holding in at 45 VA under the same conditions. Closing time runs 23 to 35 ms, opening 5 to 15 ms, which is standard for this contactor frame size. The 36 V AC control voltage must match the existing control transformer or circuit — this coil will not pull in on 24 V or 48 V. The drop-out threshold is 0.35 to 0.55 Uc (about 12.6 to 19.8 V), and the operational range is 0.85 to 1.1 Uc (30.6 to 39.6 V) at 131 °F (55 °C). If your control supply sags below 30.6 V during inrush, the coil may chatter or fail to close. Heat dissipation is 12 to 16 W at 50 Hz, so the enclosure must allow that thermal load to escape, particularly if multiple contactors are ganged. This part is classified as obsolete by the manufacturer. If you are qualifying a replacement for a new design, expect to evaluate a different TeSys F coil with the same mounting footprint and a 36 V AC rating, but verify the coil resistance and inrush profile against the contactor's minimum pick-up voltage. ## Integration notes for panel builders The coil has no built-in suppressor module, so you must add an external RC snubber or varistor across the coil terminals if the control circuit drives PLC outputs or solid-state relays — otherwise the inductive kick during de-energization can damage downstream electronics. Average coil resistance is 0.63 Ω at 68 °F (20 °C); inductance of the closed circuit is 0.09 H.","metaTitle":"Schneider Electric LX1FF036 TeSys F Contactor Coil, 36 V AC","metaDescription":"LX1FF036 TeSys F contactor coil from Schneider Electric. 36 V AC 50 Hz control circuit, 550 VA inrush, 10 Mcycles mechanical durability. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"36 V AC 50 Hz","Operating Time":"23...35 ms closing 5...15 ms opening","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 50 Hz","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/66c1901b6fdb1461f6f63050cbdd8c58.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1FF036/tesys-f-contactor-coil-lx1ff-36-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FF036/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FF036","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FF036 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}