{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FF062","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FF062","canonicalUrl":"https://aoctrl.com/schneider/LX1FF062","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FF062","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor coil, LX1FF062, 62 V AC 50 Hz, 550 VA inrush, 12-16 W heat dissipation.","salesMarkdown":"The Schneider Electric LX1FF062 is a replacement coil for TeSys F contactors, wound for 62 V AC 50 Hz control circuits. It draws 550 VA inrush at cos φ 0.3 and settles to 45 VA holding, dissipating 12 to 16 W at 50 Hz. The coil has no built-in suppressor module — you supply the RC snubber or varistor externally if the control circuit needs one. The 62 V AC 50 Hz control voltage is the coil's nominal; it operates between 0.85 and 1.1 Uc (roughly 52.7 to 68.2 V) and drops out between 0.35 and 0.55 Uc (21.7 to 34.1 V) at 55 °C. That dropout band matters if your control transformer sags under load — the coil may release earlier than a 24 VDC equivalent would. Closing time runs 23 to 35 ms, opening 5 to 15 ms, which is typical for this frame size and fine for general motor switching. This coil bolts into any TeSys F contactor frame (the LC1F range) that accepts the LX1FF coil platform. The 62 V AC 50 Hz winding is a non-standard voltage in most regions — 48 V and 110 V are more common — so verify your control transformer taps before committing. The coil draws 1.98 Ω DC resistance at 20 °C and 0.27 H inductance when closed, which helps size the suppression component if you add one externally.","metaTitle":"Schneider LX1FF062 TeSys F Contactor Coil, 62 V AC 50 Hz","metaDescription":"Obsolete Schneider TeSys F contactor coil LX1FF062, 62 V AC 50 Hz, 550 VA inrush. Sourced to order against RFQ via independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Operating time":"23...35 ms closing 5...15 ms opening","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"12...16 W 50 Hz","Device short name":"LX1FF","Average resistance":"1.98 Ohm 68 °F (20 °C)","Inrush power in VA":"550 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Control circuit type":"AC 50 Hz","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Product or Component Type":"Contactor coil","Inductance of closed circuit":"0.27 H","[Uc] control circuit voltage":"62 V AC 50 Hz","Control circuit voltage limits":"Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))","Hold-in power consumption in VA":"45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1c9fc670c68ecdbf9ea674e11202e940.pdf","sourceUrl":"https://www.se.com/th/en/product/LX1FF062/contactor-coil-tesys-f-lx1ff-62-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FF062/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LX1FF062?","answer":"Schneider does not publish a direct drop-in successor for the 62 V AC 50 Hz LX1FF coil. If your panel can accept a different control voltage, a standard-voltage TeSys F coil (48 V or 110 V AC 50 Hz) with the same LX1FF mechanical footprint is the practical migration path — but verify the coil's operating limits against your control circuit."},{"question":"What is the coil's operating temperature range?","answer":"Rated for 23 to 131 °F (-5 to 55 °C) ambient air temperature during operation."},{"question":"Does this coil include a built-in suppressor?","answer":"No. The LX1FF062 is supplied without a built-in suppressor module. You must add an external RC snubber or varistor if the control circuit requires surge suppression."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FF062","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FF062 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}