{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FF076","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FF076","canonicalUrl":"https://aoctrl.com/schneider/LX1FF076","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FF076","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor coil, LX1FF076, 76 V AC 50 Hz, 550 VA inrush, 45 VA hold-in, obsolete.","salesMarkdown":"The LX1FF076 is a replacement coil for the TeSys F contactor range, rated for 76 V AC at 50 Hz control circuits. It draws 550 VA inrush and 45 VA hold-in at 50 Hz, cos φ 0.3, dissipating 12 to 16 W at 50 Hz. The coil has no built-in suppressor module, so you need to add an external RC snubber or varistor across the coil terminals if the PLC output or relay driving it requires transient suppression. ## Integration notes The coil mounts onto the TeSys F contactor magnet assembly — it is not a standalone part. Closing time is 23 to 35 ms, opening 5 to 15 ms. The coil resistance is 2.98 Ω at 20 °C, and the closed-circuit inductance is 0.4 H. Drop-out occurs between 0.35 and 0.55 Uc, and pick-up requires 0.85 to 1.1 Uc. If your control supply sags during inrush from other loads, the coil may chatter or fail to close — check the transformer sizing and wire gauge.","metaTitle":"Schneider TeSys LX1FF076 contactor coil, 76 V AC 50 Hz, obso","metaDescription":"Schneider Electric TeSys F LX1FF076 contactor coil, 76 V AC 50 Hz. Obsolete. Sourced to order against RFQ. 550 VA inrush, 45 VA hold-in, 12-16 W dissipation.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"76 V AC 50 Hz","Operating Time":"23...35 ms closing 5...15 ms opening","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 50 Hz","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cbf214fd3ce2f72442e51069f07c61c9.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX1FF076/contactor-coil-tesys-f-lx1ff-76-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FF076/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FF076","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FF076 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}