{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FF1000","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FF1000","canonicalUrl":"https://aoctrl.com/schneider/LX1FF1000","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FF1000","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F, contactor coil LX1FF1000, 1000 V AC 50 Hz, 23...35 ms closing, 5...15 ms opening, without built-in suppressor module.","salesMarkdown":"The LX1FF1000 is a TeSys F contactor coil from Schneider Electric, designed to actuate the main contactor in a motor starter or power switching assembly. It operates on a 1000 V AC 50 Hz control circuit, drawing 550 VA inrush at 20 °C and 45 VA hold-in power at the same temperature. ## Key electrical characteristics The coil has an average resistance of 610 Ohm at 68 °F (20 °C) and an inductance of 68.5 H when closed. Its control circuit voltage limits are: drop-out at 0.35...0.55 Uc and operational range of 0.85...1.1 Uc at 50/60 Hz and 131 °F (55 °C). This means the coil reliably picks up at 850 V AC and drops out between 350 and 550 V AC, which is important for brownout ride-through planning. Operating time is 23...35 ms closing and 5...15 ms opening. That 5 ms minimum opening time is fast enough for most safety circuits but verify it coordinates with your upstream breaker's clearing time if used in a direct-on-line start. ## Thermal and mechanical performance Heat dissipation runs 12...16 W at 50 Hz, so factor that into your panel's thermal budget — a densely packed enclosure with several TeSys F contactors running continuously will need ventilation or derating. That rate suits moderate-speed conveyor or pump cycling but not high-speed stamping press applications. Ambient air temperature for operation is 23...131 °F (-5...55 °C). The coil technology is without built-in suppressor module, so you'll need to add an external RC snubber or varistor across the coil if driving it from a PLC output or solid-state relay to prevent voltage spikes.","metaTitle":"Schneider Electric LX1FF1000 TeSys F Contactor Coil, 1000 V","metaDescription":"Active TeSys F contactor coil, LX1FF1000, 1000 V AC 50 Hz control circuit. 23-35 ms closing, 5-15 ms opening. 10 Mcycles mechanical durability. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"1000 V AC 50 Hz","Operating Time":"23...35 ms closing 5...15 ms opening","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"AC 50 Hz","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/24737ec022a73139a47cc521aec5d6ca.pdf","sourceUrl":"https://www.se.com/th/en/product/LX1FF1000/tesys-f-contactor-coil-lx1ff-1000-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FF1000/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FF1000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FF1000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}