{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FG2206","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FG2206","canonicalUrl":"https://aoctrl.com/schneider/LX1FG2206","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FG2206","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F contactor coil, LX1FG2206, 265-277 V AC 60 Hz, 805 VA inrush, 55 VA hold-in, obsolete.","salesMarkdown":"The LX1FG2206 is a TeSys F contactor coil from Schneider Electric, designed as a replacement or spare coil for TeSys F contactors. It operates on a 265-277 V AC 60 Hz control circuit, drawing 805 VA inrush power and 55 VA hold-in power at 50 Hz. The coil has an average resistance of 370 Ohm at 68 °F (20 °C) and dissipates 18-24 W of heat at 50 Hz. It has a mechanical durability of 10 million cycles and a maximum operating rate of 2400 cycles per hour at 131 °F (55 °C). The control circuit voltage is 265-277 V AC 60 Hz. Dropout voltage is 0.35-0.55 Uc and operational range is 0.85-1.1 Uc at 50/60 Hz and 131 °F (55 °C). The 805 VA inrush power is the peak draw when the coil first energizes — this determines the sizing of the control transformer or power supply feeding it. The 55 VA hold-in power is the steady-state draw once the contactor is sealed, which governs continuous heat dissipation in the panel. Operating time is 20-35 ms closing and 7-15 ms opening. This is typical for a contactor coil of this size and matters for coordination in fast-switching applications like motor reversing or inching circuits. This coil is a direct replacement for TeSys F contactors that use the LX1FG coil platform. It mounts onto the contactor's magnet assembly and is wired to the control circuit. The coil has no built-in suppressor module, so an external RC snubber or varistor must be added if the control circuit requires surge suppression — common practice in PLC-driven panels where the coil is switched by a solid-state output. In a panel with multiple contactors running near the 55 °C limit, the 18-24 W heat dissipation per coil adds up — factor this into the panel's thermal budget.","metaTitle":"TeSys LX1FG2206 contactor coil, 265-277 V AC 60 Hz, obsolete","metaDescription":"Obsolete TeSys F contactor coil LX1FG2206, 265-277 V AC 60 Hz, 805 VA inrush, 55 VA hold-in. Sourced to order against RFQ. No direct replacement on record.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Operating time":"20...35 ms closing 7...15 ms opening","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"18...24 W 50 Hz","Device short name":"LX1FG","Average resistance":"370 Ohm 68 °F (20 °C)","Inrush power in VA":"805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Control circuit type":"AC 50 Hz","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Product or Component Type":"Contactor coil","Inductance of closed circuit":"51.6 H","[Uc] control circuit voltage":"265...277 V AC 60 Hz","Control circuit voltage limits":"Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))","Hold-in power consumption in VA":"55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7dd90b5c96b798dc437ba83bc952eeea.pdf","sourceUrl":"https://www.se.com/nl/en/product/LX1FG2206/tesys-f-contactor-coil-lx1fg-200-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FG2206/alternatives.json"},"ai":{"faq":[{"question":"What is the control voltage and coil draw for this part?","answer":"The control circuit voltage is 265-277 V AC 60 Hz. Inrush power is 805 VA at 50 Hz, and hold-in power is 55 VA at 50 Hz. Average coil resistance is 370 Ohm at 68 °F (20 °C)."},{"question":"Does this coil have a built-in suppressor?","answer":"No, the coil technology is listed as 'without built-in suppressor module'. An external suppression device (RC snubber or varistor) must be added if the control circuit requires it."},{"question":"What is the operating temperature range?","answer":"The ambient air temperature for operation is 23 to 131 °F (-5 to 55 °C). The maximum operating rate at 131 °F (55 °C) is 2400 cycles per hour."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FG2206","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FG2206 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}