{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FG600","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FG600","canonicalUrl":"https://aoctrl.com/schneider/LX1FG600","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FG600","rawCanonicalId":null},"summary":{"shortDescription":"TeSys F, contactor coil, LX1FG600, 600 V AC 50 Hz, 805 VA inrush, 18-24 W heat dissipation, obsolete.","salesMarkdown":"The LX1FG600 is a TeSys F contactor coil rated for 600 V AC 50 Hz control circuits, designed as a replacement coil for the TeSys F contactor range. The part is now classified as obsolete per the manufacturer's lifecycle record. ## Key electrical characteristics The coil draws 805 VA inrush at 50 Hz (cos phi 0.3) and holds at 55 VA, dissipating 18 to 24 W during continuous operation. These figures set the transformer sizing and thermal budget inside the panel. Control voltage limits are specified for 50/60 Hz at 131 °F (55 °C): drop-out occurs between 0.35 and 0.55 Uc, and the operational range is 0.85 to 1.1 Uc. This defines the hold-in margin for brownout conditions. Closing time is 20 to 35 ms, opening time 7 to 15 ms. The coil has no built-in suppressor module; an external RC snubber or varistor must be added across the coil terminals for inductive load switching. ## Mechanical and thermal ratings Ambient air temperature for operation spans 23 to 131 °F (-5 to 55 °C). Average coil resistance is 124.2 ohms at 68 °F (20 °C), with an inductance of 18.25 H in the closed circuit. These values are useful for verifying coil integrity with a multimeter during troubleshooting.","metaTitle":"TeSys LX1FG600 Contactor Coil, 600 V AC 50 Hz, Obsolete","metaDescription":"TeSys F LX1FG600 contactor coil, 600 V AC 50 Hz. Obsolete status. Sourced to order against an RFQ. 18-24 W heat dissipation, 805 VA inrush.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Operating time":"20...35 ms closing 7...15 ms opening","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Heat dissipation":"18...24 W 50 Hz","Device short name":"LX1FG","Average resistance":"124.2 Ohm 68 °F (20 °C)","Inrush power in VA":"805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Control circuit type":"AC 50 Hz","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Product or Component Type":"Contactor coil","Inductance of closed circuit":"18.25 H","[Uc] control circuit voltage":"600 V AC 50 Hz","Control circuit voltage limits":"Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))","Hold-in power consumption in VA":"55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9333e5abee64f874856c2a3ef8422b7.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1FG600/tesys-f-contactor-coil-lx1fg-600-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FG600/alternatives.json"},"ai":{"faq":[{"question":"What is the LX1FG600's listed range and category?","answer":"It belongs to the TeSys range, specifically the TeSys F contactor family. Its internal category is 22341-CONTACTOR,D,K,&F ACCESS, indicating it is a contactor accessory for those frame sizes."},{"question":"What are the key electrical ratings for the LX1FG600 coil?","answer":"The coil is rated for 600 V AC 50 Hz control circuits. Inrush power is 805 VA at 50 Hz (cos phi 0.3), hold-in power is 55 VA, and continuous heat dissipation is 18 to 24 W."},{"question":"Does the LX1FG600 include a built-in coil suppression module?","answer":"No. The coil technology is listed as 'without built-in suppressor module'. An external suppression device (RC snubber or varistor) must be added across the coil terminals to protect against voltage spikes."},{"question":"How do I source the LX1FG600 given its obsolete status?","answer":"Since the part is obsolete, it must be sourced through surplus or broker channels. Submit an RFQ with your target quantity; availability and pricing are confirmed on a per-order basis."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FG600","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FG600 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}