{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FK2206","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FK2206","canonicalUrl":"https://aoctrl.com/schneider/LX1FK2206","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FK2206","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX1FK, contactor coil, 200..220 V AC 40...400 Hz, 100...170 ms opening 40...75 ms closing.","salesMarkdown":"The LX1FK2206 is a replacement contactor coil from the Schneider TeSys range, designed to fit LX1F contactor frames. It operates on a 200...220 V AC control circuit at 40...400 Hz, with opening time of 100...170 ms and closing time of 40...75 ms. The coil carries a mechanical durability rating of 10 Mcycles and a maximum operating rate of 2400 cycles per hour at 55 °C. The 200...220 V AC control voltage at 40...400 Hz means this coil is for standard line-voltage control circuits — common in European and Asian panels where 208-240 V control transformers are typical. The 100...170 ms opening time and 40...75 ms closing time are the mechanical stroke durations; for a contactor coil, these matter when coordinating with fast-acting safety circuits or PLC-driven outputs that expect a predictable dropout delay. The 10 Mcycles mechanical durability is the theoretical life of the coil mechanism under no-load switching — in practice, electrical life under full motor load will be shorter and depends on the contactor's utilization category. ## Coil technology note This coil is supplied without a built-in suppressor module. That means the end user must add an external RC snubber or varistor across the coil terminals if the control circuit drives inductive loads or if the PLC output card requires suppression to limit back-EMF. Standard practice in a panel is to fit a suppressor across the coil — the LX1FK2206 leaves that choice to the integrator.","metaTitle":"LX1FK2206 TeSys contactor coil, 200-220 VAC, obsolete","metaDescription":"Schneider TeSys LX1FK2206 contactor coil, 200-220 VAC 40-400 Hz, 100-170 ms opening. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Operating time":"100...170 ms opening 40...75 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX1FK","Control circuit type":"AC at 40...400 Hz","Mechanical durability":"10 Mcycles","Maximum operating rate":"2400 cyc/h 55 °C","Product or component type":"Contactor coil","[Uc] control circuit voltage":"200...220 V AC 40...400 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3f1db849579b1fe4caf3812bf2954f82.pdf","sourceUrl":"https://www.se.com/th/en/product/LX1FK2206/contactor-coil-lx1f-200-220-v-ac-40400-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FK2206/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LX1FK2206?","answer":"There is no official pin-compatible successor from Schneider. For a new design, select a current TeSys coil with the same 200-220 VAC control voltage and LX1F frame compatibility. For an existing BOM, the LX1FK2206 must be sourced through surplus channels."},{"question":"What is the operating time of LX1FK2206?","answer":"Opening time is 100...170 ms and closing time is 40...75 ms. These are mechanical stroke durations for the coil plunger."},{"question":"How do I source this obsolete part?","answer":"Submit an RFQ. We source obsolete TeSys coils through our independent supply network — surplus, NOS, and refurbished stock. No price or lead time can be stated here, but we can quote against your quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FK2206","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FK2206 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}