{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1FL1106","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1FL1106","canonicalUrl":"https://aoctrl.com/schneider/LX1FL1106","factsUrl":"https://aoctrl.com/api/mcp/products/LX1FL1106","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LX1FL1106 contactor coil, 100 V AC 50 Hz / 100-110 V AC 60 Hz, without built-in suppressor module, obsolete.","salesMarkdown":"The LX1FL1106 is a replacement contactor coil from the Schneider TeSys F range, designed to energize the contactor's electromagnet and pull in the main power contacts. It operates on an AC control circuit at 50/60 Hz, with a rated control voltage of 100 V AC at 50 Hz and 100...110 V AC at 60 Hz. This coil is specified without a built-in suppressor module, meaning an external RC snubber or varistor must be added across the coil terminals if the control circuit requires transient suppression — common practice when the contactor is driven by a PLC output or electronic relay. ## What to watch when fitting this coil The LX1FL1106 is the coil-only component for a TeSys F contactor frame. It mounts onto the contactor's magnet assembly via the standard clip or screw retention — no special tools, but the contactor must be de-energized and the arc chamber removed for access. Verify the coil's AC voltage rating matches the control transformer tap before installation; a 100 V AC coil on a 110 V line will overheat and fail prematurely. Because this coil lacks a built-in suppressor, the installer must add an external RC network (e.g., Schneider part number RXZ RCP or equivalent) across the A1-A2 terminals if the control signal comes from a solid-state output. Without suppression, the inductive kickback from coil de-energization can weld relay contacts or damage the PLC driver.","metaTitle":"Schneider LX1FL1106 TeSys F Contactor Coil, 100 V AC, Obsole","metaDescription":"Obsolete LX1FL1106 contactor coil for TeSys F, 100 V AC 50 Hz / 100-110 V AC 60 Hz, 5 Mcycles mechanical durability. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX1FL","Control circuit type":"AC at 50/60 Hz","Mechanical durability":"5 Mcycles","Maximum operating rate":"1200 cyc/h 55 °C","Product or component type":"Contactor coil","[Uc] control circuit voltage":"100 V AC 50 Hz 100...110 V AC 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7a11c25de62e204a5c48b0243226f93a.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX1FL1106/contactor-coil-tesys-f-lx1fl-100-110-v-ac-60-hz-100-v-ac-50-hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1FL1106/alternatives.json"},"ai":{"faq":[{"question":"What is the control voltage for this coil?","answer":"The LX1FL1106 is rated for 100 V AC at 50 Hz and 100...110 V AC at 60 Hz. It is an AC-only coil; do not apply DC voltage."},{"question":"Does this coil include a built-in suppressor module?","answer":"No. The LX1FL1106 is specified without a built-in suppressor module. An external RC snubber or varistor must be added if the control circuit requires transient suppression."},{"question":"What is the mechanical durability of the LX1FL1106?","answer":"Rated for 5 million mechanical cycles, with a maximum operating rate of 1200 cycles per hour at 55 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1FL1106","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1FL1106 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}