{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G3QLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G3QLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G3QLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G3QLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G3QLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, for LC1G115-225/3P standard contactors, built-in bidirectional peak limiting, push-in terminals, IP20.","salesMarkdown":"## What this coil fits and why the voltage range matters The LX1G3QLSEN is the control coil for Schneider Electric's TeSys Giga series, specifically the LC1G115 through LC1G225 three-pole standard contactors. It accepts 200...500 V AC/DC at 50/60 Hz, so it covers both 240 V and 480 V control circuits common in North American panels without needing a separate transformer tap. The built-in bidirectional peak limiting coil technology suppresses inrush spikes — 215 W / 295 VA inrush drops to 8 W / 13 VA holding. That matters for PLC output card sizing: the holding draw is low enough to run multiple coils off a single 24 VDC supply without exceeding the card's per-channel current limit. ## Panel fit and wiring — push-in terminals save time Dimensions are 5.7 in high by 4.2 in wide by 3.7 in deep (144.5 x 105.7 x 94.0 mm). The coil clips onto the contactor base; no extra DIN rail space is consumed beyond the contactor's own footprint. Control circuit push-in terminals accept solid or stranded wire from AWG 26 to AWG 12, or flexible with ferrule from AWG 24 to AWG 14. No screwdriver needed for termination — strip, push, done. That shanks a few minutes per panel when you're wiring a dozen starters. ## Environmental and compliance — what the ratings actually mean Rated pollution degree 3 per IEC 60947-1, meaning it tolerates conductive dust and condensation typical in unsealed industrial enclosures. IP20 finger-safe housing keeps live terminals out of reach behind the panel door. Operating temperature range -13 to 140 °F (-25 to 60 °C) with storage from -76 to 176 °F. At altitudes up to 3000 m no derating is needed; above that, up to 5000 m, apply the derating factor from the datasheet. Certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 — the three standards that govern contactor and starter coordination. EMC immunity meets IEC 60947-4-1 criteria A and SEMI F47 voltage dip immunity, which is relevant for semiconductor fab tool power quality requirements. ## Lifecycle and sourcing — active production, quoted to order Sourced through authorized distribution channels against your BOM quantity.","metaTitle":"Schneider LX1G3QLSEN TeSys Giga Contactor Coil","metaDescription":"Schneider Electric LX1G3QLSEN TeSys Giga contactor coil, 200-500V AC/DC, for LC1G115-225/3P. Active production, UL/CSA/IEC certified. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Depth":"3.7 in (94.0 mm)","Range":"TeSys","Width":"4.2 in (105.7 mm)","title":"LX1G3QLSEN","Height":"5.7 in (144.5 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module, TeSys Giga, 200-500V AC/DC, for LC1G115-225/3P standard version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"215 W","Poles description":"3P","Inrush power in VA":"295 VA","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"8 W","Hold-in power consumption in VA":"13 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$280.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0c16e326082574078ec41bc36becffa3.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G3QLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g115225-3p-standard-version/"},"ai":{"faq":[{"question":"What contactors does LX1G3QLSEN fit?","answer":"It is the control coil for TeSys Giga LC1G115 through LC1G225 three-pole standard contactors. The 200-500 V AC/DC coil voltage covers both 240 V and 480 V control circuits."},{"question":"What compliance documentation does Schneider Electric provide for LX1G3QLSEN?","answer":"The coil carries UL 60947-4-1A, CSA C22.2 No 60947-4-1, and EN/IEC 60947-4-1 certifications. EMC immunity meets IEC 60947-4-1 criteria A and SEMI F47 voltage dip immunity standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G3QLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G3QLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}