{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G3SLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G3SLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G3SLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G3SLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G3SLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, 3P, built-in bidirectional peak limiting, push-in terminals, IP20.","salesMarkdown":"## TeSys Giga Coil for LC1G400-500/3P Contactors The LX1G3SLSEN is a control module from the TeSys Giga range, designed to drive the LC1G400-500/3P three-pole standard contactor. It operates across a wide control circuit voltage of 200-500 V AC/DC at 50/60 Hz, covering both line and DC distribution without needing a separate coil variant. The coil uses built-in bidirectional peak limiting electronics, drawing 535 VA (300 W) inrush and settling to 15.4 VA (8.6 W) hold-in power — the low hold-in reduces thermal load inside the panel and lets the contactor run cooler at sustained duty. ## Termination and Panel Fit Control circuit connections use push-in terminals accepting 0.2-2.5 mm² solid or stranded wire (AWG 26-12) and 0.25-2.5 mm² flexible with ferrules (AWG 24-14). No screw torque check needed — the spring cage holds the conductor under vibration. Dimensions are 3.7 in deep, 5.5 in wide, 6.6 in tall — the coil mounts directly on the contactor frame, adding no extra DIN-rail footprint. IP20 finger-safe protection covers the terminals. ## Operating Envelope and Durability Mechanical durability is rated at 5 million cycles, with a maximum operating rate of 600 cycles per minute at 140 °F (60 °C). Opening time spans 20-35 ms, closing 40-55 ms — consistent timing supports coordinated contactor sequencing in motor starter stacks. Ambient operating temperature range is -13 to 140 °F (-25 to 60 °C), with storage from -76 to 176 °F (-60 to 80 °C). Altitude capability reaches 3000 m without derating, 5000 m with a derating factor — relevant for high-elevation installations. ## Compliance and EMC Profile Certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 — covers contactor and starter coordination for motor circuits. Pollution degree 3 per IEC 60947-1 suits industrial environments with conductive dust or humidity. EMC immunity meets IEC 60947-4-1 with emission criteria A; radiated immunity tested to 20 V/m per EN/IEC 61000-4-3. Voltage dip immunity conforms to SEMI F47 — this matters for semiconductor fab tool power quality requirements.","metaTitle":"Schneider LX1G3SLSEN TeSys Giga Control Module 200-500V AC/DC | aoctrl","metaDescription":"Schneider LX1G3SLSEN TeSys Giga control module: 200-500V AC/DC, for LC1G400-500/3P standard version. Authorized distributor. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.7 in (93.0 mm)","Width":"5.5 in (140.0 mm)","Height":"6.6 in (167.0 mm)","IP Rating":"IP20","Coil Voltage":"200...500 V AC/DC 50/60 Hz","Operating Time":"20...35 ms opening 40...55 ms closing","Product Status":"Active","Pollution Degree":"3 IEC 60947-1","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-76...176 °F (-60...80 °C)","Mechanical Life Cycles":"5 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"-13...140 °F (-25...60 °C)","Permissible Ambient Air Temperature Around The Device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$280.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a21410307ab2cea220404efb022c245a.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G3SLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g400500-3p-standard-version/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G3SLSEN/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G3SLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G3SLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}