{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G3TEHEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G3TEHEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G3TEHEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G3TEHEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga, contactor coil LX1G3TEHEA, 48-130V AC/DC 50/60 Hz, 3P, for LC1G630-800/3P advanced version, with built-in bidirectional peak limiting.","salesMarkdown":"This coil carries EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No. 60947-4-1 certifications. That means it is tested and listed for contactor duty in industrial control panels — not just a generic relay coil. The pollution degree 3 rating per IEC 60947-1 confirms it tolerates conductive pollution typical in factory environments without conformal coating. ## Physical integration and wiring Control circuit wiring uses push-in terminals accepting 0.2 to 2.5 mm² solid or stranded (with ferrule) or two 0.5 to 1.0 mm² conductors. Strip length and ferrule spec are standard; no special tooling needed. ## Environmental limits and operating envelope Permissible ambient around the device extends to -40 to 70 °C at Uc, but the 60 °C operating ceiling is the hard limit for cycle-rated duty. Altitude derating starts at 3000 m; above that, apply the derating factor per IEC 60947-1. Opening time is 20 to 35 ms; closing time is 40 to 55 ms. Those figures matter for coordination in safety circuits or sequential starting — you cannot treat it as instantaneous. EMC immunity meets IEC 60947-4-1 with criteria A, including 20 V/m radiated field immunity per EN/IEC 61000-4-3 and SEMI F47 voltage dip immunity for semiconductor fab equipment.","metaTitle":"TeSys Giga LX1G3TEHEA Contactor Coil, 48-130V AC/DC, 3P","metaDescription":"Active-production TeSys Giga control module for LC1G630-800/3P contactors. 48-130V AC/DC coil with built-in bidirectional peak limiting. EN/IEC 60947-4-1, UL, CSA. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"211 mm","Width":"192 mm","Height":"130 mm","IP Rating":"IP20","Coil Voltage":"48...130 V AC/DC 50/60 Hz","Operating Time":"20...35 ms opening 40...55 ms closing","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-1","Temp Storage Max":"80 °C","Temp Storage Min":"-60 °C","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-60...80 °C","Mechanical Life Cycles":"5 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"-25...60 °C","Permissible Ambient Air Temperature Around The Device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a28f9f8f4b870bb6bbfac429d9fd8b10.pdf","sourceUrl":"https://www.se.com/ie/en/product/LX1G3TEHEA/control-moduletesys-giga48130v-ac-dcfor-lc1g630800-3p-advanced-version/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G3TEHEA/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G3TEHEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G3TEHEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}