{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G3TLSEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G3TLSEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G3TLSEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G3TLSEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys contactor coil, LX1G3TLSEA, 3-pole, control circuit 200-500 V AC/DC, push-in terminals, IP20.","salesMarkdown":"The LX1G3TLSEA is a Schneider TeSys contactor coil built for 3-pole contactors. It accepts a control voltage range of 200...500 V AC/DC, covering a wide range of control power supplies. Operating time spec (20...35 ms open, 40...55 ms close) tells you this coil responds fast enough for standard motor starting and stopping. If you're holding a spare for a conveyor or pump starter that cycles heavily, the 5 Mcycles mechanical durability means it outlasts most duty cycles before you need to swap it. ## Wiring and Mounting Fit Push-in terminals accept solid or ferruled stranded wire from 0.2 to 2.5 mm², AWG 26 to 12, with or without cable end sleeves. No screwdriver needed for the control circuit connection—saves time when you're rebuilding a panel after a coil failure and every minute of downtime costs production. IP20 rated (IEC 60529), pollution degree 3 per IEC 60947-1, and ambient operating range -13 to 140 °F (-25 to 60 °C). That's standard for enclosed panel installations; no special sealing required unless the cabinet is washdown-rated. Standards compliance includes EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. That puts it on the same compliance footing as the contactor it mates with—no extra documentation chase for the quality folder. The 200...500 V AC/DC control voltage range matches common control transformer outputs. Operating limits are 0.8...1.1 Uc and drop-out at 0...0.45 Uc, providing good brownout ride-through. Built-in bidirectional peak limiting coil technology suppresses voltage spikes on the control circuit. Maximum operating rate of 600 cycles per minute at 60 °C suits high-speed picking or sorting lines. For a spare that might go into a fast-cycling machine, this rating confirms the coil won't thermally saturate.","metaTitle":"Schneider LX1G3TLSEA TeSys Contactor Coil, 200-500 V AC/DC","metaDescription":"Active production Schneider LX1G3TLSEA TeSys contactor coil, 200-500 V AC/DC, IP20, push-in terminals. UL/IEC rated. Source to order. RFQ for BOM commitment.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"8.3 in (211 mm)","Range":"TeSys","Width":"7.6 in (192 mm)","Height":"5.1 in (130 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Poles description":"3P","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$413.89","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bea84030deba43a6ac1151eae7e7e3fc.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G3TLSEA/alternatives.json"},"ai":{"faq":[{"question":"What is the range of the LX1G3TLSEA?","answer":"It belongs to the Schneider TeSys range of contactors and control components."},{"question":"What compliance documentation does Schneider provide for the LX1G3TLSEA?","answer":"The coil meets EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. These standards cover performance and safety for contactor coils."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G3TLSEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G3TLSEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}