{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G3TLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G3TLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G3TLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G3TLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G3TLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, 3-pole, built-in bidirectional peak limiting, IP20, push-in terminals.","salesMarkdown":"## Coil voltage and control circuit The LX1G3TLSEN is a TeSys Giga contactor coil rated for a control circuit voltage of 200-500 V AC/DC at 50/60 Hz, making it a direct fit for the LC1G630-800/3P standard contactor range. Built-in bidirectional peak limiting electronics suppress voltage spikes at dropout, reducing EMI and extending the life of the control circuit contacts. Inrush power is 390 W (670 VA) and hold-in power drops to 11 W (17 VA), so the control transformer sizing is driven by the inrush demand, not the steady-state draw. ## Operating margins and durability Operating time is 20-35 ms opening and 40-55 ms closing, which coordinates with the contactor's arc chamber timing for reliable switching under load. Mechanical durability is rated at 5 million cycles, and the maximum operating rate is 600 cycles per minute at 60 °C — this coil is built for high-duty-cycle applications like conveyor or pump control. Control circuit voltage limits: operational range is 0.8-1.1 Uc at 60 °C, and dropout occurs between 0-0.45 Uc — the wide dropout margin prevents nuisance dropouts during voltage sags. ## Sourcing and compliance Approvals include EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1, covering industrial control equipment for panel builds in North America and Europe. EMC immunity meets IEC 60947-4-1 with 20 V/m radiated immunity per EN/IEC 61000-4-3 and voltage dips/interruptions immunity per SEMI F47 — suitable for semiconductor fab and other sensitive environments.","metaTitle":"Schneider Electric LX1G3TLSEN Contactor Coil, 200-500V AC/DC","metaDescription":"Schneider Electric LX1G3TLSEN TeSys Giga contactor coil, 200-500V AC/DC, 50/60 Hz. Active production. Built-in bidirectional peak limiting. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1G3TLSEN","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module, TeSys Giga, 200-500V AC/DC, for LC1G630-800/3P standard version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"390 W","Poles description":"3P","Inrush power in VA":"670 VA","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"11 W","Hold-in power consumption in VA":"17 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$280.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8f4977c6a1ac9b276d0708eb3a2f6c63.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G3TLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g630800-3p-standard-version/"},"ai":{"faq":[{"question":"What standards does LX1G3TLSEN comply with?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1, plus EMC immunity per IEC 60947-4-1 and SEMI F47 for voltage dips."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G3TLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G3TLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}