{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4QBEEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4QBEEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G4QBEEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4QBEEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys contactor coil LX1G4QBEEA, 4-pole, 24...48 V AC/DC 50/60 Hz, 3.7 x 5.5 x 5.7 in.","salesMarkdown":"## Contactor coil for TeSys frames The LX1G4QBEEA is a replacement coil from Schneider's TeSys range, designed for 4-pole contactors. Control circuit voltage spans 24…48 V AC/DC, 50/60 Hz, with built-in bidirectional peak limiting that suppresses the back-EMF spike on de-energization — no external flyback diode needed. Dimensions are 3.7 in deep (94.0 mm) by 5.5 in wide (140.7 mm) by 5.7 in high (144.5 mm), matching the mounting footprint of compatible TeSys contactor frames. ## Electrical and mechanical characteristics Inrush power is 205 W DC or 330 VA at 48 V AC, while hold-in consumption drops to 3.6 W DC or 6.2 VA at 48 V AC — a typical ratio for TeSys coils. Opening time ranges 20…35 ms, closing 40…55 ms, and the coil is rated for 5 million mechanical cycles. Control circuit limits: pick-up is guaranteed between 0.8 and 1.1 Uc, drop-out between 0 and 0.45 Uc. IP20 protects against finger contact during panel installation. Ambient temperature range for operation is -13…140 °F (-25…60 °C); storage tolerance is wider at -76…176 °F (-60…80 °C). The coil is certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1.","metaTitle":"Schneider LX1G4QBEEA TeSys Contactor Coil, 24-48V AC/DC","metaDescription":"Schneider TeSys contactor coil LX1G4QBEEA for 4-pole contactors, 24...48 V AC/DC 50/60 Hz, IP20, push-in terminals, active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.7 in (94.0 mm)","Range":"TeSys","Width":"5.5 in (140.7 mm)","Height":"5.7 in (144.5 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"205.0 W DC","Poles description":"4P","Inrush power in VA":"330 VA 48 V AC, 50 Hz","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"24...48 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"3.6 W DC","Hold-in power consumption in VA":"6.2 VA 48 V AC, 50 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$421.28 – $515.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d99090d2fbcef0abf7cf4e769220841e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G4QBEEA/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications of this coil?","answer":"Control voltage 24…48 V AC/DC, 4-pole, dimensions 3.7 x 5.5 x 5.7 in, IP20, built-in peak limiting, 5 Mcycles mechanical durability."},{"question":"What compliance standards does this coil meet?","answer":"It meets EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4QBEEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4QBEEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}