{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4QLSEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4QLSEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G4QLSEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4QLSEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys contactor coil LX1G4QLSEA, 4-pole, 200-500 V AC/DC, with built-in bidirectional peak limiting.","salesMarkdown":"The LX1G4QLSEA is a 4-pole contactor coil in the TeSys range, accepting 200-500 V AC/DC with bidirectional peak limiting. It is obsolete; confirm drop-out at 0...0.45 Uc at 60°C. The opening time of 20...35 ms and closing time of 40...55 ms are typical for a modular contactor coil in this frame; sequence interlocks or safety circuits that depend on timing should allow these windows. Mechanical durability is rated at 5 million cycles — that's not the limit for the entire contactor, only the coil armature, so this component will outlast many electro-mechanical cycles in normal motor-switching duty. The coil accepts control circuit conductors via push-in terminals sized for 0.2 to 2.5 mm² solid or stranded (AWG 26 to 12), and flexible wire with end sleeves from 0.25 to 2.5 mm² (AWG 24 to 14). You can mount this in enclosures up to 3000 m altitude without derating, and up to 5000 m with de-rating. The IP20 protection means a finger-safe enclosure is fine for the panel interior, but not exposed to dripping liquids. Ambient temperature range for operation is -13 to 140°F (-25 to 60°C). The coil draws 155 W DC peak inrush and 255 VA at 480 V AC 60 Hz, holding at 3.4 W DC and 13.4 VA — that is the steady-state burden on the control transformer.","metaTitle":"Schneider LX1G4QLSEA Contactor Coil, 200-500V AC/DC, Obsolet","metaDescription":"Obsolete LX1G4QLSEA contactor coil from Schneider TeSys range. 200-500 V AC/DC control, 4-pole, built-in peak limiting. Sourced to order while stock lasts. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.7 in (94.0 mm)","Range":"TeSys","Width":"5.5 in (140.7 mm)","Height":"5.7 in (144.5 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"155.0 W DC","Poles description":"4P","Inrush power in VA":"255 VA 480 V AC, 60 Hz","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"3.4 W DC","Hold-in power consumption in VA":"13.4 VA 480 V AC, 60 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$421.28","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d99090d2fbcef0abf7cf4e769220841e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G4QLSEA/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the LX1G4QLSEA?","answer":"The depth is 3.7 inches (94.0 mm)."},{"question":"What series does the LX1G4QLSEA belong to?","answer":"TeSys."},{"question":"What compliance documentation is available for the LX1G4QLSEA?","answer":"The coil complies with EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4QLSEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4QLSEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}