{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4QLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4QLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G4QLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4QLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G4QLSEN contactor coil, 200-500 V AC/DC, 4-pole, for LC1G115-225 standard contactors, IP20, push-in terminals.","salesMarkdown":"## Coil for the LC1G115-225 frame The LX1G4QLSEN is a control module — the coil for Schneider Electric's TeSys Giga contactor range, specifically the LC1G115 through LC1G225 four-pole standard versions. It's the replaceable solenoid that pulls the contactor in and holds it closed. Rated for a wide control voltage band of 200...500 V AC/DC at 50/60 Hz, it covers common global control voltages from 208 V to 480 V without needing a separate transformer tap. ## Built-in peak limiting holds the line The coil uses built-in bidirectional peak limiting — that means the inrush spike is clamped at 215 W / 295 VA, and the sealed hold-in power drops to just 8 W / 13 VA. The low hold power keeps the heat rise inside the contactor envelope manageable, which matters when the contactor is packed tight on a DIN rail with other devices. Opening time is 20...35 ms, closing time 40...55 ms. That's fast enough for most motor-start and isolation duties, but the asymmetry means the coil's dropout delay is shorter than its pickup — a consideration if you're sequencing contactors in a reversing or bypass scheme. ## Rated for the panel environment The LX1G4QLSEN carries approvals to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 — the core standards for contactors and motor-starters. Pollution degree 3 per IEC 60947-1 means it's rated for the conductive dust and humidity typical of industrial control panels, not just clean office air. IP20 housing protects against finger contact but not water ingress — standard for panel-mounted control gear. The push-in terminals accept solid or stranded wire from 26 AWG to 12 AWG, with or without ferrules, which speeds wiring on the line. ## Active production, sourced per RFQ Mechanical durability is rated at 5 million cycles — that's the contactor frame's life, not just the coil. At a maximum operating rate of 600 cycles per minute at 140 °F (60 °C), the coil keeps up with high-speed jogging or indexing applications without overheating.","metaTitle":"Schneider Electric LX1G4QLSEN TeSys Giga Contactor Coil","metaDescription":"Active Schneider LX1G4QLSEN TeSys Giga contactor coil, 200-500V AC/DC, 4P, for LC1G115-225. IP20, push-in terminals. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Depth":"3.7 in (94.0 mm)","Range":"TeSys","Width":"5.5 in (140.7 mm)","title":"LX1G4QLSEN","Height":"5.7 in (144.5 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module, TeSys Giga, 200-500V AC/DC, for LC1G115-225/4P standard version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"215 W","Poles description":"4P","Inrush power in VA":"295 VA","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"8 W","Hold-in power consumption in VA":"13 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$285.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b8311451dfdc77dc4dfc253501f7b2ce.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G4QLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g115225-4p-standard-version/"},"ai":{"faq":[{"question":"How do I get current pricing and availability for LX1G4QLSEN?","answer":"Pricing and stock are confirmed at quote time against your BOM quantity. Submit an RFQ through this listing; we source through authorized distribution and confirm lead time and volume pricing on request."},{"question":"What compliance documentation does Schneider Electric provide for LX1G4QLSEN?","answer":"The coil is certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. It also meets EMC immunity per IEC 60947-4-1 with emission criteria A and immunity to radiated interference at 20 V/m per EN/IEC 61000-4-3, plus voltage dip immunity per SEMI F47."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4QLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4QLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}