{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4RBEEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4RBEEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G4RBEEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4RBEEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga control module, LX1G4RBEEA, 24-48V AC/DC, 4-pole, for LC1G265-330/4P advanced contactors.","salesMarkdown":"The LX1G4RBEEA is a control module from the TeSys Giga range, designed as the coil assembly for the LC1G265-330/4P advanced version 4-pole contactor. Opening time is 20...35 ms and closing time is 40...55 ms, which is typical for a contactor of this frame size. ## Fit and integration details Dimensions are 167 mm high, 185 mm wide, and 93 mm deep. The control circuit uses push-in termination — accepts 0.2...2.5 mm² solid or stranded without ferrules, or 0.25...2.5 mm² flexible with ferrules. Two-cable parallel entry is supported for daisy-chaining control wiring, accepting 0.5...1.0 mm² rigid or stranded with ferrules. The permissible ambient temperature around the device at rated control voltage Uc is -40...70 °C. The module is certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 — the core contactor and motor-starter standards for North America and Europe. EMC immunity conforms to IEC 60947-4-1 with emission test criteria A, and immunity to radiated radio-electrical interference at 20 V/m per EN/IEC 61000-4-3. It also meets SEMI F47 voltage dips and interruptions immunity, relevant for semiconductor fab equipment.","metaTitle":"Schneider Electric LX1G4RBEEA TeSys Giga Control Module, 24-","metaDescription":"Control module for LC1G265-330/4P advanced contactors. 24-48V AC/DC coil, push-in terminals, IP20. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Depth":"93.0 mm","Range":"TeSys","Width":"185.0 mm","title":"LX1G4RBEEA","Height":"167.0 mm","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module,TeSys Giga,24-48V AC/DC,for LC1G265-330/4P advanced version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 conforming to IEC 60947-1","Quantity per set":"1","Device short name":"LX1G","Poles description":"4P","Operating altitude":"3000 m without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Maximum operating rate":"600 cyc/mn 60 °C","Connections - terminals":"Control circuit: push-in termination 1 cable(s) 0.2...2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit: push-in termination 1 cable(s) 0.25...2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 Control circuit: push-in termination 2 cable(s) 0.5...1.0 mm² rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 conforming to IEC 60529","Product or component type":"Contactor coil","[Uc] control circuit voltage":"24...48 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational: 0.8...1.1 Uc (at 60 °C) Drop-out: 0...0.45 Uc (at 60 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-25...60 °C","Permissible ambient air temperature around the device":"-40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$631.23","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b247abcd51c0b24587e21e5bf646d722.pdf","sourceUrl":"https://www.se.com/au/en/product/LX1G4RBEEA/control-moduletesys-giga2448v-ac-dcfor-lc1g265330-4p-advanced-version/"},"ai":{"faq":[{"question":"What are the key ratings for the LX1G4RBEEA?","answer":"The control circuit voltage is 24...48 V AC/DC at 50/60 Hz. Opening time is 20...35 ms, closing time 40...55 ms. Mechanical durability is 5 Mcycles, maximum operating rate is 600 cycles per minute at 60 °C. Operating temperature range is -25...60 °C."},{"question":"What standards does the LX1G4RBEEA comply with?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. It also meets SEMI F47 for voltage dips immunity and has EMC immunity per IEC 60947-4-1 with 20 V/m radiated immunity per EN/IEC 61000-4-3."},{"question":"What wire sizes does the push-in terminal accept?","answer":"The control circuit push-in terminals accept 0.2...2.5 mm² solid or stranded without ferrules, 0.25...2.5 mm² flexible with ferrules, and for two-cable parallel entry 0.5...1.0 mm² rigid or stranded with ferrules. AWG equivalents are 26...12, 24...14, and 20...18 respectively."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4RBEEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4RBEEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}