{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4RLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4RLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G4RLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4RLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G4RLSEN control module, 200-500V AC/DC, 4-pole, for LC1G265-330/4P contactors, push-in terminals, IP20.","salesMarkdown":"## Coil voltage range and what it means for your panel The LX1G4RLSEN is a control module — the coil driver — for TeSys Giga contactors in the LC1G265 through LC1G330 4-pole standard range. It accepts a 200...500 V AC/DC control circuit voltage, so it spans both 240 V and 480 V control transformers without a tap change. The built-in bidirectional peak limiting coil technology keeps inrush to 300 W / 530 VA and hold-in to 9 W / 16.1 VA. That means the control transformer can be sized for the steady-state draw, not the inrush spike — a real advantage when multiple contactors share a single control supply. Operating limits are 0.8...1.1 Uc for pick-up and 0...0.45 Uc for drop-out at 60 °C ambient. If your control voltage sags below 80 % of nominal during a motor start, the contactor may drop out — factor that into your control transformer sizing and voltage drop calculations. ## Durability and switching rate for high-cycle applications Mechanical durability is rated at 5 million cycles, with a maximum operating rate of 600 cycles per minute at 60 °C. For a conveyor system cycling once every 10 seconds, that's over 500 days of continuous operation before mechanical wear becomes a consideration. Opening time is 20...35 ms and closing time is 40...55 ms. In a safety circuit that needs to break within a single mains cycle (16.7 ms at 60 Hz), this coil's opening time is marginal — the contactor's own arc extinction time adds to the total break time. Plan for a separate fast-acting safety contactor if your stop time budget is under 50 ms. ## Standards, environmental ratings, and installation fit The module carries EN/IEC 60947-4-1 and UL 60947-4-1A / CSA C22.2 No 60947-4-1 approvals — the core standards for contactors and motor-starters. Pollution degree 3 per IEC 60947-1 means it's rated for industrial environments with conductive dust or occasional condensation. IP20 finger protection per IEC 60529 — the terminals are touch-safe but the module is not washdown-rated. Mount it inside a panel with at least IP54 enclosure protection for wet or dusty areas. Operating altitude is 3000 m without derating, 5000 m with derating factor. At high-altitude installations above 3000 m, the air's lower dielectric strength and reduced cooling capacity mean you'll need to derate the contactor's thermal current — consult the TeSys Giga derating curves for your site elevation. Dimensions are 3.7 in (93 mm) deep × 7.3 in (185 mm) wide × 6.6 in (167 mm) high. The push-in terminals on the control circuit accept 0.2...2.5 mm² solid or stranded wire (AWG 26...12) without ferrules, or 0.25...2.5 mm² flexible with ferrules (AWG 24...14). No screwdriver needed for the control wiring — strip, push, and the spring cage holds. ## Sourcing and lifecycle reality Sourced against an RFQ through authorized distribution channels.","metaTitle":"Schneider LX1G4RLSEN TeSys Giga Control Module 200-500V AC/DC 4P | aoctrl","metaDescription":"Schneider LX1G4RLSEN TeSys Giga control module: 200-500V AC/DC, for LC1G265-330/4P standard version. Authorized distributor. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Depth":"3.7 in (93.0 mm)","Range":"TeSys","Width":"7.3 in (185.0 mm)","title":"LX1G4RLSEN","Height":"6.6 in (167.0 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module, TeSys Giga, 200-500V AC/DC, for LC1G265-330/4P standard version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"300 W","Poles description":"4P","Inrush power in VA":"530 VA","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"9 W","Hold-in power consumption in VA":"16.1 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$285.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c0bf7e557b7c6454c6e980ef49f84af1.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G4RLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g265330-4p-standard-version/"},"ai":{"faq":[{"question":"Where can I buy LX1G4RLSEN and get a price?","answer":"The module is sourced to order against an RFQ through independent industrial distribution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4RLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4RLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}