{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4SEHEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4SEHEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G4SEHEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4SEHEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX1G4SEHEA control module coil, 4-pole, 48...130 V AC/DC, built-in bidirectional peak limiting, push-in terminals.","salesMarkdown":"The LX1G4SEHEA: Opening time runs 20–35 ms, closing 40–55 ms – fast enough for most motor starts but with a deliberate close that avoids hammering the contacts on the mating power pole. Inrush draw peaks at 295 W DC or 380 VA at 120 V AC; hold-in drops to 5.3 W DC or 10.1 VA at 120 V AC. That low hold power means you can run it off a smaller control transformer without oversizing. Terminals are push-in on the control circuit – 0.2–2.5 mm² solid or stranded, or 0.25–2.5 mm² with ferrules. No screwdriver needed for the coil wiring, and the connection stays solid under vibration.","metaTitle":"Schneider LX1G4SEHEA TeSys Contactor Coil, 48-130V AC/DC, 4P","metaDescription":"Schneider LX1G4SEHEA TeSys control module coil, 48-130 V AC/DC, 4 poles. Active production, sourced to order. EN/IEC 60947-4-1, UL. Depth 93 mm. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.7 in (93.0 mm)","Range":"TeSys","Width":"7.3 in (185.0 mm)","Height":"6.6 in (167.0 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"295.0 W DC","Poles description":"4P","Inrush power in VA":"380 VA 120 V AC, 60 Hz","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"48...130 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"5.3 W DC","Hold-in power consumption in VA":"10.1 VA 120 V AC, 60 Hz","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$421.28","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0166104ba81ecf159ba7491016186a52.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G4SEHEA/alternatives.json"},"ai":{"faq":[{"question":"What is LX1G4SEHEA's listed depth?","answer":"Depth is 3.7 in (93.0 mm)."},{"question":"What range does LX1G4SEHEA belong to?","answer":"It is part of the TeSys range."},{"question":"What compliance documentation does this part carry?","answer":"It complies with EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4SEHEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4SEHEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}