{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4SLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4SLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G4SLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4SLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G4SLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, 4-pole, built-in bidirectional peak limiting, IP20, 5 Mcycles mechanical durability.","salesMarkdown":"## Coil voltage and what it means for your panel The LX1G4SLSEN is the control coil module for TeSys Giga LC1G400-500/4P contactors, accepting 200-500 V AC/DC at 50/60 Hz — a wide-range coil that covers most global control voltages from 208 V to 480 V without needing a transformer tap change. Built-in bidirectional peak limiting electronics handle the inrush (300 W / 535 VA) and hold-in (8.6 W / 15.4 VA) power, so the PLC or relay output driving this coil sees a controlled load — no external varistor or RC snubber needed across the coil terminals. ## Switching speed and endurance for high-cycle lines Opening time is 20-35 ms, closing time 40-55 ms — fast enough for most motor start/stop sequences but not so fast that contact bounce becomes a problem on the main poles. Rated for 5 million mechanical cycles and a maximum operating rate of 600 cycles per minute at 60 °C ambient — this coil keeps up with high-speed pick-and-place or indexing conveyors without derating. ## Standards and environmental tolerance Certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 — the coil meets the full contactor standard, not just a component-level listing, so the panel builder gets a single UL listing for the contactor assembly. Pollution degree 3 per IEC 60947-1 means it tolerates conductive dust and humidity typical in industrial enclosures without conformal coating. IP20 finger-safe terminals with push-in wiring accept 0.2-2.5 mm² solid or stranded with ferrule. Operates from -25 °C to 60 °C ambient and stores from -60 °C to 80 °C. Altitude rating is 3000 m without derating, 5000 m with derating — fine for most installations outside high-altitude mining. ## Sourcing and lifecycle status Quoted to order against your BOM quantity; availability and current pricing confirmed at RFQ time through authorized distribution channels.","metaTitle":"TeSys LX1G4SLSEN Contactor Coil, 200-500V AC/DC, 4P","metaDescription":"Active TeSys Giga contactor coil LX1G4SLSEN, 200-500V AC/DC 50/60 Hz, 4P. Built-in bidirectional peak limiting. UL/CSA/IEC 60947-4-1. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Depth":"3.7 in (93.0 mm)","Range":"TeSys","Width":"7.3 in (185.0 mm)","title":"LX1G4SLSEN","Height":"6.6 in (167.0 mm)","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module, TeSys Giga, 200-500V AC/DC, for LC1G400-500/4P standard version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"300 W","Poles description":"4P","Inrush power in VA":"535 VA","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"8.6 W","Hold-in power consumption in VA":"15.4 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$285.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/29abc88dc2eafd8c7ddcd9ac6a1e5983.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G4SLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g400500-4p-standard-version/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4SLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4SLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}