{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4TLSEA","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4TLSEA","canonicalUrl":"https://aoctrl.com/schneider/LX1G4TLSEA","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4TLSEA","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys LX1G4TLSEA, contactor coil, 4 poles, 200-500 V AC/DC control circuit, push-in terminals.","salesMarkdown":"The LX1G4TLSEA: Coil technology uses built-in bidirectional peak limiting, which means you can skip external snubber networks for moderate line transients. ## Panel Fit & Wiring Dimensions: depth 11.06 in (281 mm), width 7.6 in (192 mm), height 5.1 in (130 mm) — fits the standard TeSys contactor footprint. IP20 terminal shrouds protect live parts during maintenance. Rated IP20 conforms to IEC 60529, so the coil can be installed in a protected cabinet without additional finger-safe covers. ## Compliance & Environmental Limits Listed under standards EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. EMC immunity meets criteria A per IEC 60947-4-1 and SEMI F47 voltage dip immunity. Ambient operating range -13 to +140 °F (-25 to +60 °C); storage -76 to +176 °F (-60 to +80 °C). Full voltage tolerance at up to 140 °F. Operates to 3000 m without derating, and to 5000 m with a derating factor. Active lifecycle status means the part is current. Sourcing is straightforward via RFQ — we quote to order. ## Performance & Durability Opening time 20–35 ms, closing 40–55 ms. Mechanical durability rated at 5 Mcycles. Maximum operating rate 600 cycles/min at 60 °C. Coil circuit voltage limits: operational 0.8…1.1 Uc at 60 °C; drop-out 0…0.45 Uc. Designed for 4-pole contactors; the short device name LX1G indicates this coil series within TeSys.","metaTitle":"Schneider LX1G4TLSEA TeSys Contactor Coil, 200-500V AC/DC","metaDescription":"Active LX1G4TLSEA TeSys contactor coil, 200-500 V AC/DC control, 4 poles, push-in terminals. UL/CSA listed. RFQ for availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"11.06 in (281 mm)","Range":"TeSys","Width":"7.6 in (192 mm)","Height":"5.1 in (130 mm)","Category":"US10I1222328","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Poles description":"4P","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$433.51","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f050fe19ac0f6560424c6a1798f8ec9f.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1G4TLSEA/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of LX1G4TLSEA?","answer":"Depth is 11.06 in (281 mm). This is the longest dimension; ensure panel clearance for coil removal."},{"question":"What is the range of LX1G4TLSEA?","answer":"It belongs to the Schneider TeSys range, identified by the short device name LX1G. This covers a family of contactors and coils for motor control."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4TLSEA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4TLSEA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}