{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1G4TLSEN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1G4TLSEN","canonicalUrl":"https://aoctrl.com/schneider/LX1G4TLSEN","factsUrl":"https://aoctrl.com/api/mcp/products/LX1G4TLSEN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Giga LX1G4TLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, 4-pole, built-in bidirectional peak limiting, IP20, active production.","salesMarkdown":"## Control coil for LC1G630-800/4P contactors The LX1G4TLSEN is a control module from the TeSys Giga range, designed specifically for the LC1G630-800/4P standard version contactor. It operates on a 200-500 V AC/DC control circuit at 50/60 Hz, covering both AC and DC supply rails without needing a separate rectifier module. The coil uses built-in bidirectional peak limiting technology, which clamps voltage spikes at the coil terminals — this extends the life of the control relay contacts and reduces radiated EMI in the panel. Inrush power hits 390 W (670 VA), then drops to 11 W (17 VA) holding, so the control transformer sizing needs to handle the inrush peak, not just the sealed VA. ## Operating envelope and integration Opening time is 20-35 ms, closing 40-55 ms — fast enough for motor starting duty cycles on pumps and conveyors, but not a high-speed switching coil. Maximum operating rate is 600 cycles per minute at 60 °C, which suits frequent start-stop applications within the TeSys Giga frame. Mechanical durability is rated at 5 million cycles, and the coil operates from -25 °C to 60 °C ambient with storage down to -60 °C. Pollution degree 3 per IEC 60947-1 means it handles conductive pollution in industrial enclosures without conformal coating on the coil assembly. Control circuit termination uses push-in terminals accepting 0.2-2.5 mm² solid or stranded wire (AWG 26-12), or 0.25-2.5 mm² flexible with ferrules. The IP20 finger-safe housing protects against accidental contact during panel wiring. ## Compliance and sourcing posture Sourced to order against the BOM quantity through independent distribution. The coil mates only with the LC1G630-800/4P contactor; confirm the contactor frame before committing the line item.","metaTitle":"TeSys LX1G4TLSEN contactor coil, 200-500V AC/DC, 4-pole","metaDescription":"Schneider TeSys Giga LX1G4TLSEN contactor coil for LC1G630-800/4P. 200-500V AC/DC control voltage, built-in peak limiting. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1G4TLSEN","Category":"US10I1222329","Standards":"EN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1","description":"Control module, TeSys Giga, 200-500V AC/DC, for LC1G630-800/4P standard version","Operating time":"20...35 ms opening 40...55 ms closing","Coil technology":"Built-in bidirectional peak limiting","lifecycle_stage":"current","Pollution degree":"3 IEC 60947-1","Quantity per Set":"1","Device short name":"LX1G","Inrush power in W":"390 W","Poles description":"4P","Inrush power in VA":"670 VA","Operating altitude":"9842.52 ft (3000 m) without derating 5000 m with derating factor","Mechanical durability":"5 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"600 cyc/mn 140 °F (60 °C)","Connections - terminals":"Control circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18","IP degree of protection":"IP20 IEC 60529","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"200...500 V AC/DC 50/60 Hz","Electromagnetic compatibility":"EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47","Control circuit voltage limits":"Operational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))","Hold-in power consumption in W":"11 W","Hold-in power consumption in VA":"17 VA","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient Air Temperature for Operation":"-13...140 °F (-25...60 °C)","Permissible ambient air temperature around the device":"-40...158 °F (-40...70 °C) at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$285.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f050fe19ac0f6560424c6a1798f8ec9f.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1G4TLSEN/control-module-tesys-giga-200500v-ac-dc-for-lc1g630800-4p-standard-version/"},"ai":{"faq":[{"question":"What contactor does LX1G4TLSEN fit?","answer":"This control coil is designed for the TeSys Giga LC1G630-800/4P standard version contactor. It is a 4-pole coil with 200-500 V AC/DC control voltage. Verify the contactor frame matches before ordering."},{"question":"What compliance documentation does LX1G4TLSEN carry?","answer":"The coil is certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1. It also meets SEMI F47 voltage dip immunity for semiconductor equipment and EMC immunity per IEC 60947-4-1 with 20 V/m radiated field testing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1G4TLSEN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1G4TLSEN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}