{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1LB036","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1LB036","canonicalUrl":"https://aoctrl.com/schneider/LX1LB036","factsUrl":"https://aoctrl.com/api/mcp/products/LX1LB036","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX1LB036, replacement coil, 36 V AC 50 Hz, 75 VA inrush power, 8 VA sealed.","salesMarkdown":"The LX1LB036 is a replacement coil from the Schneider TeSys range, designed to fit TeSys contactors and motor starters that take the LX1 coil platform. It's the part that pulls the contactor in when you apply 36 V AC at 50 Hz. Rated for 36 V AC 50 Hz control voltage, with an inrush draw of 75 VA that drops to 8 VA once sealed. That 75 VA inrush is what you need to budget for in your control transformer sizing — it's a short spike, but it's real. ## What the specs mean on the bench Coil resistance measures 11.01 Ohm at 20 °C, ±10%. That's your go-to check when you're bench-testing a used pull or troubleshooting a no-pickup — a shorted or open coil will read way off that value. Inductance is 0.95 mH, which plays into the inrush current profile. The 8 VA sealed consumption means the coil stays cool in continuous duty — no extra derating for a panel that's packed tight. Mount it on the contactor, wire the A1-A2 terminals, and it's done.","metaTitle":"Schneider TeSys LX1LB036 coil, 36 V AC 50 Hz, 75 VA inrush","metaDescription":"Schneider TeSys LX1LB036 replacement coil for contactors, 36 V AC 50 Hz control voltage, 75 VA inrush / 8 VA sealed. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1LB036","Category":"18402-WORLD SERVICE PARTS(CONTROL ACCESS)","description":"coil LX1-LB - 36 V AC","lifecycle_stage":"current","Device short name":"LX1","Average resistance":"11.01 Ohm at 68 °F (20 °C) +/- 10 %","Value of inductance":"0.95 mH","Power consumption in VA":"75 VA AC 0.55 50 Hz inrush 8 VA AC 0.28 50 Hz sealed","Product or Component Type":"Coil","[Uc] control circuit voltage":"36 V AC 50 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fa47f7e941ffebac7ea016509d419050.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1LB036/coil-lx1lb-36-v-ac/"},"ai":{"faq":[{"question":"What is the control voltage for LX1LB036?","answer":"It's a 36 V AC coil rated at 50 Hz. The inrush power is 75 VA, dropping to 8 VA sealed."},{"question":"What TeSys range does this coil belong to?","answer":"It's part of the Schneider TeSys range, specifically the LX1 coil platform used across TeSys contactors and motor starters."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1LB036","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1LB036 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}