{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1LB056","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1LB056","canonicalUrl":"https://aoctrl.com/schneider/LX1LB056","factsUrl":"https://aoctrl.com/api/mcp/products/LX1LB056","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX1 series replacement coil, LX1LB056, 56 V AC 50 Hz control circuit voltage, 75 VA inrush / 8 VA sealed power consumption, 28.09 Ohm resistance.","salesMarkdown":"The LX1LB056 is a replacement coil from the Schneider Electric TeSys range, designed for contactors and motor starters that use the LX1 coil platform. It's the part that pulls the contactor in — no coil, no switching. Rated for a 56 V AC 50 Hz control circuit, this coil draws 75 VA inrush at 0.55 power factor and settles to 8 VA sealed at 0.28 power factor. That inrush-to-sealed ratio is typical for AC-operated contactor coils — the high inrush pulls the armature in, then the sealed VA holds it closed with less heat. Coil resistance measures 28.09 Ohm at 20 °C, ±10 %, with an inductance of 0.95 mH. These values matter for troubleshooting — an open coil or a shorted turn shows up as a resistance reading outside that band. Classified under 18402-WORLD SERVICE PARTS(CONTROL ACCESS), meaning it's stocked as a serviceable spare, not a design-in component for new panels. That's fine for a replacement coil — you're swapping it into an existing TeSys contactor, not specifying it for a greenfield build. This coil mounts directly onto the TeSys contactor magnet assembly — no adapter, no bracket. The LX1 coil family shares the same mechanical footprint across the D-range contactors, so fit is consistent if you're replacing a failed coil on an LC1D or LC1F frame. Wire the 56 V AC supply to the coil terminals with proper polarity for the AC circuit — AC coils aren't polarity-sensitive, but the suppression network (if fitted) may be. Verify the control transformer is sized for the 75 VA inrush; a marginal transformer can cause the contactor to chatter on pull-in.","metaTitle":"Schneider LX1LB056 TeSys Coil, 56 V AC 50 Hz, Active","metaDescription":"Schneider Electric LX1LB056 TeSys replacement coil, 56 V AC 50 Hz control voltage, 28.09 Ohm resistance, 75 VA inrush / 8 VA sealed. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"56 V AC 50 Hz","Product Status":"Active","Main Product Or Component Type":"Coil"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a053819947aa3007e31450522d924363.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1LB056/coil-lx1lb-56-v-ac-50hz/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX1LB056/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1LB056","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1LB056 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}