{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX1LC330","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX1LC330","canonicalUrl":"https://aoctrl.com/schneider/LX1LC330","factsUrl":"https://aoctrl.com/api/mcp/products/LX1LC330","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX1LC330, replacement coil, 330 V AC 50/60 Hz control circuit, 12-18 VA sealed, 392.321 Ohm ±10%.","salesMarkdown":"The LX1LC330 is a replacement coil from the TeSys range, designed for LC1 series contactors. It is the wound component that energizes the contactor's magnetic circuit, pulling the main poles closed when the control voltage is applied. Control circuit voltage is 330 V AC at 50 Hz and 380 V AC at 60 Hz — a dual-frequency rating that covers 50 Hz and 60 Hz mains without a separate tap. Power consumption sits at 12-18 VA sealed (holding) and 170-230 VA inrush at 60 Hz, 0.3 A sealed / 0.55 A inrush. The inrush figure governs the sizing of the control transformer or PLC output driving this coil; the sealed draw is what the thermal budget sees in continuous operation. ## Key electrical parameters for fit verification Average resistance is 392.321 Ohm ±10% at 20 °C. This is the value to compare against a failed coil when troubleshooting an intermittent dropout — a shorted or open winding will deviate well outside the ±10% band. Inductance is 0.107 mH with the magnetic circuit closed (contactor engaged). Open-circuit inductance will differ; this figure is the operating value once the armature seals.","metaTitle":"TeSys LX1LC330 Coil, 330 V AC 50/60 Hz, Active","metaDescription":"TeSys LX1LC330 replacement coil for LC1 contactors. 330 V AC 50/60 Hz control voltage, 12-18 VA sealed. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","title":"LX1LC330","Category":"18402-WORLD SERVICE PARTS(CONTROL ACCESS)","description":"coil LX1-LC - 330 V AC 50Hz,","lifecycle_stage":"current","Device short name":"LX1","Average resistance":"392.321 Ohm +/- 10 %","Value of inductance":"0.107 mH closed circuit","Power consumption in VA":"12...18 VA AC 0.3 60 Hz sealed 170...230 VA AC 0.55 60 Hz inrush","Product or Component Type":"Coil","[Uc] control circuit voltage":"330 V AC 50 Hz 380 V AC 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9cbfe1a9710c6dc2afbf9f6aa650a6bd.pdf","sourceUrl":"https://www.se.com/us/en/product/LX1LC330/coil-lx1lc-330-v-ac-50hz/"},"ai":{"faq":[{"question":"What is the LX1LC330's listed range?","answer":"The LX1LC330 belongs to the TeSys range from Schneider Electric."},{"question":"What is the control voltage for this coil?","answer":"The control circuit voltage is 330 V AC at 50 Hz and 380 V AC at 60 Hz."},{"question":"What is the sealed power consumption of the LX1LC330?","answer":"Sealed power consumption is 12-18 VA at 60 Hz, 0.3 A. Inrush is 170-230 VA at 60 Hz, 0.55 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX1LC330","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX1LC330 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}