{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4D7LD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4D7LD","canonicalUrl":"https://aoctrl.com/schneider/LX4D7LD","factsUrl":"https://aoctrl.com/api/mcp/products/LX4D7LD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LX4D7LD, contactor coil, 200 V DC standard, for 80 A contactor, obsolete.","salesMarkdown":"The LX4D7LD is a replacement coil for the TeSys Deca contactor range, specifically wound for a 200 V DC control circuit and designed to fit the 80 A frame contactor. It pulls in at 22 W inrush and holds at the same 22 W, with a coil resistance of 1747 Ω at 20 °C. The 75 ms time constant tells you the coil's magnetic field builds at a rate that matches the contactor's mechanical response — fast enough for standard motor starting, not so fast it slams the armature. ## Control voltage limits — the real-world fit The drop-out threshold is 0.1 to 0.3 Uc (20 to 60 V DC), and the operational range is 0.85 to 1.1 Uc (170 to 220 V DC) at up to 55 °C. That means a 200 V nominal supply needs to stay above 170 V at the coil terminals under load — a long cable run or a sagging power supply will drop it out. No built-in suppressor module, so you'll want a free-wheeling diode across the coil if the drive circuit doesn't already have one. This coil mounts directly onto the TeSys Deca 80 A contactor frame. The DC standard coil means the contactor is intended for a DC control bus — common in panel designs where the control voltage is rectified from the AC line or fed from a battery-backed DC supply. Ambient operating range is -5 to 60 °C, so it's fine inside a ventilated enclosure but not for direct outdoor exposure.","metaTitle":"TeSys LX4D7LD Contactor Coil, 200 V DC, for 80 A Contactor","metaDescription":"Obsolete TeSys LX4D7LD contactor coil, 200 V DC standard, for 80 A contactor. 22 W inrush/hold, 10 Mcycles mechanical. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"200 V DC","Time Constant":"75 ms","Product Status":"Active","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"DC standard","Mechanical Life Cycles":"10 Mcycles","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...140 °F (-5...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/34e42635719cb386ea3cb55f19e4b61d.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX4D7LD/contactor-coil-tesys-deca-lx4d7-200-v-dc-standard-for-80-a-contactor/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4D7LD/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4D7LD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4D7LD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}