{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4D7WD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4D7WD","canonicalUrl":"https://aoctrl.com/schneider/LX4D7WD","factsUrl":"https://aoctrl.com/api/mcp/products/LX4D7WD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca contactor coil, LX4D7WD, 543 V DC standard, for 80 A contactor.","salesMarkdown":"The LX4D7WD is a DC-operated contactor coil from the Schneider Electric TeSys Deca range, designed as the replacement coil for a 80 A TeSys contactor frame. It is a dedicated control-circuit component — not a standalone contactor — and it carries a 543 V DC control circuit voltage, which means it is sized for high-voltage DC control schemes typical in industrial switchgear where a separate DC supply powers the coil bus. The coil draws 22 W inrush and 22 W hold-in power at 20 °C, with an average resistance of 14058 Ω. Its control circuit is DC standard without a built-in suppressor module, so the panel builder must add a free-wheeling diode or varistor across the coil terminals to suppress the inductive kickback when de-energizing — standard practice for DC coils driving PLC or relay outputs. Because the coil is obsolete, the integrator or MRO planner should verify that the existing contactor frame (80 A TeSys Deca) is still serviceable with an alternative coil voltage if a 543 V DC supply is not available. The drop-out voltage range is 0.1 to 0.3 Uc and the operational range is 0.85 to 1.1 Uc at 55 °C, so a replacement coil must match these limits for reliable pick-up and drop-out. The coil mounts directly onto the TeSys Deca contactor base — no special tooling required. The time constant of 75 ms governs the coil's magnetic build-up, which means the contactor's main poles close approximately 75 ms after the control voltage is applied. This delay is short enough for most sequencing logic but should be accounted for in timing-sensitive interlock circuits. Operating ambient temperature range is -5 to 60 °C (23 to 140 °F). The coil's hold-in power is continuous-rated at 22 W, so the enclosure must dissipate that heat when the contactor is held in for extended periods — factor it into the panel's thermal budget, especially in sealed cabinets with multiple contactors.","metaTitle":"Schneider Electric LX4D7WD TeSys Contactor Coil, 543 V DC, O","metaDescription":"Schneider Electric LX4D7WD TeSys Deca contactor coil, 543 V DC standard for 80 A contactor. Obsolete status; sourced to order against an RFQ. Mechanical durability 10 Mcycles.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactor & Starter Coils"],"specifications":{"Range":"TeSys","Category":"22341-CONTACTOR,D,K,&F ACCESS","Time constant":"75 ms","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX4D7","Inrush power in W":"22 W 68 °F (20 °C))","Average resistance":"14058 Ohm 68 °F (20 °C)","Control circuit type":"DC standard","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"3600 cyc/h 140 °F (60 °C)","Product or Component Type":"Contactor coil","[Uc] control circuit voltage":"543 V DC","Control circuit voltage limits":"Drop-out: 0.1...0.3 Uc (at Operational: 0.85...1.1 Uc (at <131 °F (55 °C))","Hold-in power consumption in W":"22 W 68 °F (20 °C)","Ambient Air Temperature for Operation":"23...140 °F (-5...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d54e4a1a4e84658259379f930bfa1296.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX4D7WD/tesys-deca-contactor-coil-lx4d7-543-v-dc-standard-for-80-a-contactor/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4D7WD/alternatives.json"},"ai":{"faq":[{"question":"What is the control voltage for this coil?","answer":"The control circuit voltage is 543 V DC, with a drop-out range of 0.1 to 0.3 Uc and an operational range of 0.85 to 1.1 Uc at 55 °C."},{"question":"What contactor does this coil fit?","answer":"It is designed for the TeSys Deca range 80 A contactor frame. It is a replacement coil, not a standalone contactor."},{"question":"Does the coil include a built-in suppressor?","answer":"No. The coil technology is listed as without built-in suppressor module. An external free-wheeling diode or varistor must be added across the coil terminals for inductive kickback suppression."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4D7WD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4D7WD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}