{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4FF300","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4FF300","canonicalUrl":"https://aoctrl.com/schneider/LX4FF300","factsUrl":"https://aoctrl.com/api/mcp/products/LX4FF300","rawCanonicalId":null},"summary":{"shortDescription":"Telemecanique TeSys LX4FF300, contactor coil, 300 V DC, 30...40 ms closing, 30...50 ms opening, without built-in suppressor module.","salesMarkdown":"## Coil for FF contactor frame, 300 V DC control The LX4FF300 is a replacement coil for the FF-frame contactor in the TeSys range, rated for 300 V DC control circuits. It lands before the window or it doesn't go — the operating time is 30...40 ms closing and 30...50 ms opening, which is the critical path for sequencing logic in a panel rebuild. Coil technology is without built-in suppressor module, so the panel builder must add external flyback suppression (diode or RC snubber) across the coil terminals. The average resistance is 160.7 Ω inrush and 34910 Ω holding at 68 °F (20 °C), typical for a DC low-consumption design. ## Control voltage limits and thermal range Operational voltage window is 0.85...1.1 Uc at 131 °F (55 °C), meaning the coil holds in reliably from 255 V DC to 330 V DC. Drop-out threshold is 0.15...0.2 Uc (45...60 V DC), so the contactor releases cleanly on a sag without chattering. Ambient air temperature for operation is 23...131 °F (-5...55 °C).","metaTitle":"TeSys LX4FF300 contactor coil, 300 V DC, active production","metaDescription":"TeSys LX4FF300 contactor coil, 300 V DC, 30-40 ms closing. Active lifecycle. Sourced to order against an RFQ. No built-in suppressor module.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"300 V DC","Operating Time":"30...40 ms closing 30...50 ms opening","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"DC low consumption","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c5726dc69e672ad9f5b2a80a07bcef11.pdf","sourceUrl":"https://www.se.com/th/en/product/LX4FF300/contactor-coil-ff-300-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4FF300/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4FF300","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4FF300 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}