{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4FJ045","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4FJ045","canonicalUrl":"https://aoctrl.com/schneider/LX4FJ045","factsUrl":"https://aoctrl.com/api/mcp/products/LX4FJ045","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX4FJ045 contactor coil, 45 V DC, for FJ frame contactors, active production.","salesMarkdown":"The LX4FJ045 is a replacement contactor coil from the TeSys range, built for FJ frame contactors. It's the part you swap when the coil opens up or the control voltage goes missing — no need to replace the whole contactor if the main poles and arc chambers are still good. This coil runs on 45 V DC, low-consumption type, so it's meant for DC control circuits — not a 24 V or 48 V nominal bus. The drop-out threshold sits between 20% and 35% of Uc at 55 °C, meaning it'll drop the contactor cleanly if the control voltage sags below about 9 to 16 V DC. Operational range is 85% to 110% of Uc at the same temperature, so you've got some headroom on a 48 V supply, but don't push it past 49.5 V. ## Timing and coil characteristics — what matters on site Opening time runs 45 to 60 ms, closing time 50 to 60 ms. That's tight enough for most motor control and interlocking circuits — you're not going to lose a race condition with a PLC scan cycle unless the logic is milliseconds-critical. The coil draws about 1.98 ohms inrush at 20 °C, then settles to 526.1 ohms holding — standard DC economizer behavior, so your power supply sees a big thump on pickup, then a low hold current. No built-in suppressor module on this coil, so you'll want a free-wheeling diode or RC snubber across the coil if you're switching it with a PLC output or solid-state relay; the inductive kickback will fry a transistor output without one. Rated for ambient operation from -5 °C to 55 °C — fine for most indoor panels and mild outdoor enclosures. If the panel sits in a hot machine bay or direct sun, check the derating: the holding resistance climbs with temperature, so at 55 °C the coil might not pull in reliably if the supply voltage is at the low end of the operational range.","metaTitle":"TeSys LX4FJ045 Contactor Coil, 45 V DC, Active","metaDescription":"TeSys LX4FJ045 replacement contactor coil for FJ contactors. 45 V DC control, 45-60 ms opening time. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Coil Voltage":"45 V DC","Operating Time":"45...60 ms opening 50...60 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"DC low consumption","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6d4f0ad7480ffa75f516373a97c37796.pdf","sourceUrl":"https://www.se.com/uk/en/product/LX4FJ045/contactor-coil-fj-45-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4FJ045/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4FJ045","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4FJ045 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}