{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4FJ110","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4FJ110","canonicalUrl":"https://aoctrl.com/schneider/LX4FJ110","factsUrl":"https://aoctrl.com/api/mcp/products/LX4FJ110","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LX4FJ110 contactor coil, 110 V DC, 6 W DC low consumption, for LC1F400 contactor, without built-in suppressor module, discontinued.","salesMarkdown":"## Overview The LX4FJ110 is a Schneider TeSys F contactor coil rated 110 V DC, drawing 6 W in steady-state DC low-consumption mode, designed to drop into the LC1F400 contactor frame. It ships without a built-in suppressor module and carries a mechanical life of 10 Mcycles at up to 2400 cycles per hour at 55 °C. Compared to the LX1FJ048, which is an AC 40...400 Hz coil rated 48 V and 15 VA, the LX4FJ110 runs on 110 V DC and draws only 6 W — a straight DC control circuit swap without rewiring the panel is not possible because the coil voltage and control-circuit type differ.","metaTitle":"Schneider LX4FJ110 TeSys F contactor coil, 110 V DC, 6 W (discontinued)","metaDescription":"Schneider LX4FJ110 TeSys F contactor coil for LC1F400, 110 V DC, 6 W DC low consumption, discontinued since 2020-11-01. Surplus sourcing via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Range":"TeSys","Category":"US10I1222341","Operating time":"45...60 ms opening 50...60 ms closing","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Device short name":"LX4FJ","Inrush power in W":"1000 W 68 °F (20 °C))","Average resistance":"12.7 Ohm inrush 68 °F (20 °C) 2660 Ohm holding 68 °F (20 °C)","Control circuit type":"DC low consumption","Mechanical durability":"10 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Product or Component Type":"Contactor coil","Inductance of closed circuit":"270 H","[Uc] control circuit voltage":"110 V DC","Control circuit voltage limits":"Drop-out 0.2...0.35 Uc 131 °F (55 °C)) Operational 0.85...1.1 Uc 131 °F (55 °C))","Hold-in power consumption in W":"6 W 68 °F (20 °C)","Ambient Air Temperature for Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$344.40 – $526.63","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f476462c1bdc890dcc4b88574b8d2525.pdf","sourceUrl":"https://www.se.com/us/en/product/LX4FJ110/tesys-f-contactor-coil-lx4fj-110-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4FJ110/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4FJ110","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4FJ110 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}