{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LX4FJ180","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LX4FJ180","canonicalUrl":"https://aoctrl.com/schneider/LX4FJ180","factsUrl":"https://aoctrl.com/api/mcp/products/LX4FJ180","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LX4FJ180 contactor coil, 180 V DC, DC low consumption, 45...60 ms opening, 50...60 ms closing, without built-in suppressor module.","salesMarkdown":"The Schneider Electric LX4FJ180 is a replacement contactor coil from the TeSys range, designed for FJ-frame contactors. It operates on 180 V DC control voltage and is a DC low-consumption type, meaning it draws a higher inrush current to pull in, then drops to a low holding current — 29.9 Ω inrush vs 7669 Ω holding at 20 °C. This is the coil only, not the full contactor; you swap it into an existing FJ contactor base. The 180 V DC control circuit voltage is the nominal coil rating — the part pulls in reliably between 0.85 and 1.1 Uc (153–198 V DC at 55 °C) and drops out between 0.2 and 0.35 Uc (36–63 V DC at 55 °C). If your control voltage sits outside that band, the coil won't hold or won't drop cleanly. Operating time runs 45–60 ms opening, 50–60 ms closing — typical for a DC coil of this size, but worth checking if your safety circuit timing budget is tight. The coil ships without a built-in suppressor module. That means you need to add an external flyback diode or RC snubber across the coil terminals if your PLC output or relay driving it can't handle the inductive kickback. On a DC coil this size, the back-EMF spike can weld relay contacts or kill a transistor output without suppression. ## Deployment context The 180 V DC control voltage is common in battery-backed or DC-distributed control systems — think UPS-fed panels in process plants or DC bus architectures.","metaTitle":"Schneider LX4FJ180 TeSys Contactor Coil, 180 V DC, Obsolete","metaDescription":"Schneider Electric TeSys LX4FJ180 contactor coil, 180 V DC, DC low consumption. Obsolete lifecycle; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Coil Voltage":"180 V DC","Operating Time":"45...60 ms opening 50...60 ms closing","Product Status":"Active","Temp Operating Max":"55 °C","Temp Operating Min":"-5 °C","Control Circuit Type":"DC low consumption","Main Product Or Component Type":"Contactor coil","Ambient Air Temperature Operation":"23...131 °F (-5...55 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e26a55459fc1d87d4991d2448b912e44.pdf","sourceUrl":"https://www.se.com/vn/en/product/LX4FJ180/contactor-coil-fj-180-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LX4FJ180/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LX4FJ180","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LX4FJ180 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}